Page 39 - 1000V Product Range
P. 39

ARC GUARD SYSTEM








                                         ABB’s TVOC Arc Guard System stands at the forefront of electrical
                                         safety solutions, specifically tailored for industrial and commercial
                                         environments.

                                         The Arc Guard system employs susceptible sensors to swiftly detect
                                         characteristic signatures of electrical arcs, enabling a rapid response
                                         to mitigate potential hazards. Upon detection, the system orchestrates
                                         a controlled shutdown of the affected circuit, effectively quenching
                                         the arc and preventing further damage to equipment and personnel.
                                         Distinguished by a modular design, the Arc Guard System seamlessly
                                         integrates into existing electrical panels. Advanced features, such
                                         as communication capabilities and adjustable sensitivity settings,
                                         contribute to its adaptability across diverse applications. The system’s
                                         compliance with international standards underscores its reliability and
                                         commitment to safety.
                                         w
                                         ABB’s Arc Guard System offers insights into arc fault analysis, aiding in
                                         diagnostics and preventative maintenance.


        PROTECT YOUR VALUABLE RESOURCES
        WITH TVOC-2, ABB’S ARC GUARD SYSTEM

                SIL-2 certified according to IEC 61508 and IEC 62062
                                                       Breaker trip command
                            Real time status and       is received and with
                            update information
                                                       ABB’s Emax2 circuit
                            provided regarding
                                                       breakers, the total arc
                            the location of the fault  clearing time in less
                            and associated
                                                       than 50 milliseconds
                            information
                                   A trip signal is
                                   communicated to the
                                   breaker upstream of           Arc fault identified within 1
                                                                 millisecond via both optical
                                   the fault
                                                                 sensors (expandable up to
                                                                 30) and current monitoring
                                                                 sensors































                                                                                                1000V Products | 39
   34   35   36   37   38   39   40   41   42   43   44