Page 117 - ABB_Pilot_Devices _Catalogues
P. 117

ABB  PILOT DEVICES – THE COMPLETE OFFERING                                        115

          —

          Compact range
          Technical data




                           —
                           Buzzer CB
                           Color        Light and sound       Current            Illuminance  Sound press level
                                        output
                                                              mA                 lx
                                                              Min.      Max.     Min.   Max.  (dB/10cm)
                           Voltage range 24 V AC / DC
                           l l  Red     Pulsation   63        75       150       450          ≥90
                           l l  Yellow  Pulsation   63        75       70        300          ≥90
                           l l  Green   Continuous  43        53       150       600          ≥90
                           l l  Black   Pulsation   58        72       –         –            ≥90
                           l l  Black   Continuous  40        50       –         –            ≥90
                           Voltage range 110 ... 30 V AC
                           l l  Red     Pulsation   71        81       70        300          ≥90
                           l l  Yellow  Pulsation   72        87       150       450          ≥90                     04
                           l l  Green   Continuous  50        60       150       600          ≥90
                           l l  Black   Pulsation   42        54       –         –            ≥90
                           l l  Black   Continuous  40        50       –         –            ≥90
                           Voltage range 110 ... 130 V DC
                           l l  Red     Pulsation   13        18       5         50           ≥80
                           l l  Yellow  Pulsation   13        18       5         50           ≥80
                           l l  Green   Continuous  13        18       15        100          ≥80
                           l l  Black   Pulsation   13        18       –         –            ≥80
                           l l  Black   Continuous  13        18       –         –            ≥80
                           Voltage range 230 V AC
                           l l  Red     Pulsation   70        84       150       450          ≥90
                           l l  Yellow  Pulsation   72        82       70        300          ≥90
                           l l  Green   Continuous  50        62       350       900          ≥90
                           l l  Black   Pulsation   42        54       –         –            ≥90
                           l l  Black   Continuous  43        53       –         –            ≥90
                           Note: The testing distance of illuminance is 2 mm between top lens and sensor surface. Clean test environment, supply voltage at 50 / 60 Hz with
                           harmonized wave and without high frequency.
                           Fluctuation of rated voltage: -10% to +10%.






























                                                                                                                  1SFC151078S0201