Page 53 - ABB_Pilot_Devices _Catalogues
P. 53
ABB PILOT DEVICES – THE COMPLETE OFFERING 51
—
Modular plastic range
Technical data
02
Color Current Illuminance Anti-inductive Main wavelength Color
peak voltage temperature
mA lx
Min. Max. Min. Max. V Nm K
Voltage range 220 V DC
l l Red 7 10 700 2300 15 620 ... 625 –
l l Green 7 10 2400 8000 15 515 ... 520 –
l l Yellow 7 10 800 3100 15 585 ... 590 –
l l Blue 7 10 1200 4350 15 465 ... 470 –
l Clear 7 10 1400 7000 15 – 8000 ... 12000
Voltage range 230 V AC
l l Red 8 12 900 3100 15 620 ... 625 –
l l Green 8 12 3000 11500 15 515 ... 520 –
l l Yellow 8 12 1000 3400 15 585 ... 590 –
l l Blue 7 11 1500 5300 15 465 ... 470 –
l Clear 7 11 1800 8500 15 – 8000 ... 12000
Voltage range 380 V AC
l l Red 8 12 900 3100 15 620 ... 625 –
l l Green 8 12 3000 11500 15 515 ... 520 –
l l Yellow 8 12 1000 3400 15 585 ... 590 –
l l Blue 8 12 1500 5300 15 465 ... 470 –
l Clear 8 12 1800 8500 15 – 8000 ... 12000
Voltage range 415 V AC
l l Red 8 12 900 3100 15 620 ... 625 –
l l Green 8 12 3000 11500 15 515 ... 520 –
l l Yellow 8 12 1000 3400 15 585 ... 590 –
l l Blue 8 12 1500 5300 15 465 ... 470 –
l Clear 8 12 1800 8500 15 – 8000 ... 12000
Voltage range 230 V AC high anti-inductive voltage (1)
l l Red 8 12 480 1700 55 620 ... 625 –
l l Green 6 11 1500 5800 55 515 ... 520 –
l l Yellow 8 12 530 1900 55 585 ... 590 –
l l Blue 6 11 850 3100 55 465 ... 470 –
l Clear 6 11 1000 5200 55 – 8000 ... 12000
Note:
The testing distance of illuminance is 2 mm, between top of lens and the sensor surface. Clean test environment, supply voltage at 50/60 Hz with
harmonized wave and without length high frequency.
Rated voltage tolerance of LED blocks: -30% to +10%
(1) Higher threshold to light up LED to be used in applications where there is risk of large induced voltages.
1SFC151031S0201