Page 744 - ABB_Motor _Protection_and_Control_catalogue_20221216
P. 744

6/6              ABB  MOTOR PROTECTION AND CONTROL

          —

          Thermal and electronic overload relays




          Thermal overload relays







          IEC: rated operational power AC-3  400 V  0.06 … 7.5 kW              0.06 … 18.5 kW  11 … 37 kW                        18.5 … 45 kW              37 … 75 kW                37 … 110 kW
          UL/CSA: 3-phase hp-ratings      480 V  1/2 … 10 hp                   1/2 … 25 hp   15 … 50 hp                          30 ... 75 hp              50 … 100 hp               50 … 150 hp
          Fitting to contactors                B6, B7, MC1, MC2                AF09 ... AF38  AF40, AF52, AF65                   AF80, AF96                AF116, AF140, AF146       AF190, AF205
          Type                                T16                              TF42          TF65                                TF96                      TF140DU                   TA200DU
          Current range                        0.10 … 16 A                     0.10 … 38 A   22 … 67 A                           40 … 96 A                 66 … 142 A                66 … 200 A
          Trip class                           10                              10            10                                  10                        10A                       10A
          Suitable for 1-phase                 yes                             yes           yes                                 yes                       yes                       yes
          Single mounting kit                  DB16                            DB42          DB65                                DB96                      -                         DB200

   06





          Electronic overload relays
          with integrated CT




          IEC: rated operational power AC-3  400 V  0.06 … 7.5 kW  0.06 … 7.5 kW  4 … 22 kW  7.5 … 37 kW                         22 … 55 kW                30 … 75 kW                37 … 110 kW               75 … 200 kW
          UL/CSA: 3-phase hp-ratings      480 V  1/2 … 10 hp   1/2 … 10 hp     5 … 30 hp     15 … 50 hp                          30 ... 75 hp              50 … 100 hp               50 … 150 hp               100 … 300 hp
          Fitting to contactors                B6, B7, BC6, BC7, VB6, VB7,   AF09 … AF38  AF26 ... AF38  AF40, AF52, AF65        AF80, AF96                AF116, AF140, AF146       AF190, AF205              AF265, AF305, AF370
                                               VBC6, VBC7
          Type                                E16DU            EF19            EF45          EF65                                EF96                      EF146                     EF205                     EF370
          Current range                        0.10 … 18.9 A   0.10 … 18.9 A   9 … 45 A      20 … 70 A                           20 … 100 A                54 … 150 A                63 … 210 A                115 … 380 A
          Trip class                           10E, 20E, 30E selectable                                                          10E, 20E, 30E selectable
          Suitable for 1-phase                 no              no              no            no                                  no                        no                        no                        no
          Single mounting kit                  DB16E           DB19EF          DB45EF        -                                   DB96                      -                         -                         -






          Electronic overload relays
          with external separate CT





          IEC: rated operational power AC-3  400 V  75 … 250 kW  132 … 400 kW                250 … 710 kW
          UL/CSA: 3-phase hp-ratings      480 V  100 … 400 hp  200 … 500 hp                  600 … 900 hp
          Fitting to contactors                AF400, AF460    AF580, AF750, AF1250          AF1350, AF1650, AF2050
          Type                                EF460               EF750                      EF1250DU
          Current range                        150 … 500 A     250 … 800 A                   375 … 1250 A
          Trip class                           10E, 20E, 30E selectable
   739   740   741   742   743   744   745   746   747   748   749