Page 10 - DEHN protects Smart Grids
P. 10

Safe service and maintenance                                                                                               Five safety rules                                                                  Part No.
                                                                                                                                       1. Disconnect completely
            DEHN safety equipment                                                                                                                                       Switching sticks                                  763 611
                                                                                                                                                                        Nominal voltage (UN): 1...36 kV
                                                                                                                                                                        Fuse tongs                                        765 042
                                                                                                                                                                        Nominal voltage (UN): 1...36 kV
                                                                                                                                       2. Secure against re-connection
                                                                                                                                                                        Insulating plug                                   785 640
                                                                                                                                                                        Insulating blade                                  785 642
                                                                                                                                                                        Lock-out system                                   785 637
                                                                                                                                       3. Verify that the installation is dead
                                                                                                                                                                        HSA high-voltage indicator                        767 539
                                                                                                                                                                        Nominal voltage (UN): 110...420 kV, for high-voltage overhead lines


                                                                                                                                                                        PHE 4 voltage detector                            783 280
                                                                                                                                                                        Nominal voltage (UN): 60...132 kV, for switchgear installations
                                                                                                                                                                        and overhead lines
                                                                                                                                                                        Voltage detector kit                              767 724
                                                                                                                                                                        Nominal voltage (UN): 20 kV, for switchgear installations and
                                                                                                                                                                        overhead lines; transport case included.

                                                                                                                                       4. Carry out earthing and short-circuiting
                                                                                                                                                                        Earthing and short-circuiting devices
                                                                                                                                                                        Easy and flexible configuration of individual earthing
                                                                                                                                                                        and short-circuiting devices for your installation at:
                                                                                                                                                                        short link: de.hn/safety-rules


                                                                                                                                                                        Earthing sticks                                   761 016


                                                                                                                                       5. Provide protection against adjacent live parts
                                                                                                                                                                        Insulating protective shutters                    763 211

                                                                                                                                                                        Insulating mats                                   785 458
                                                                                                                                                                        For insulating standing areas




                                                                                                                                       Application                                                                        Part No.
            Safe right down the line…                        … and on the job!                                                         Set of warning signs

            Work on electrical systems is becoming more and more    •  Insulated sticks                                                                                 Set of warning signs                              700 050
            demanding. Make sure you use safe and reliable equipment.   •  Voltage detectors

                                                             •  Earthing and short-circuiting devices
            DEHN offers tested products and reliable services which                                                                    Wireless inspection camera
            protect you against injury caused by arc faults and secure   •  Covering material and blankets                                                              Wireless inspection camera                        766 390
            the availability of your systems. This gives you, as the    •  Arc fault tested personal protective equipment                                               Protected against bridging up to 123 kV
            employer, legal certainty.
                                                                                                                                       Passive arc fault protection DEHNcare
                                                                                                                                                                        Safety helmet for electricians                    785 705

                                                                                                                                                                        Arc-fault-tested face shield                      785 722
                                                                                                                                                                        Class 2

                                                                                                                                                                        Arc-fault-tested protective gloves                785 810
                                                                                                                                                                        with long gauntlet

                                                                                                                                                                        Protective coat                                   785 756
                                                             Further information is available on the Internet:
                                                                                                                                                                        Storage rucksack                                  785 443

                                                              Short link: de.hn/safety-pd



    18                                                                                                                                                                                                                                    19
   5   6   7   8   9   10   11   12