Page 360 - Din prodcuts 2020
P. 360

4/6               ELECTRICAL INSTALL ATION SOLUTIONS FOR BUILDINGS   2CHC 420 001 C0201




          —
          Auxiliary elements and accessories for MCBs and RCDs
                                                                                              MOD-S
          Selection tables


                                                                           S 200
  4
                           Combination of S200/SD200 with motor        Combination of auxiliary elements with SN201
                           operating device                                             ST    MOD-S








                                                                                 S               ST-F/UR  H   H
                                                    MOD-S



                              S200 series                              SN 201
                              SD200**
                                                                                                          S/H  S/H
                                                                                                              (H)
                                            ST      MOD-S
                                                                                 IH
                                                                                             S/H  S/H
                                                                                                 (H)
                            ST     Shunt trip for S 200 MCB  S2C-A...
                            MOD-S*  Motor operating device  S2C-CM...
                           *  in case of using S 200 coupled with DDA 200, MOD-S doesn’t
                            operate in case of earth-leakage fault  MOD-S
                           **  S200 series MCBs and SD200 switch disconnectors up to 3P or
                            2P+ST can be coupled with MOD-S
                                                                                             H   H
                                                    MOD-S
                              S200 series                              IH      Coupling interface/ auxiliary   SN201-IH
                              SD200**                                          contact
                                                                       S       Signal contact          SN201-S
                                            ST      MOD-S
                              S200P**                                  H       Auxiliary contact       S2C-H6R
                           Combination of S200P with motor operating   S/H     Signal/auxiliary contact  S2C-S/H6R
                           device
                                                                       S/H (H)  Signal/auxiliary contact used as   S2C-S/H6R
                                            ST      MOD-S
                                                                               auxiliary contact
                                                                              F 200 *                ARH
                                                                       ST-F    Shunt trip of F200 RCD  F2C-A
                                                                       UR      Undervoltage release    S2C-UA



                                                    MOD-S




                              S200P**


                                            ST      MOD-S


                            ST     Shunt trip for S 200 MCB S  S2C-A...
                            MOD-S*  Motor operating device  S2C-CM...
                            *  in case of using S 200 coupled with DDA 200, MOD-S doesn’t
                            operate in case of earth-leakage fault
                           ** S200P MCBs in all poles variants can be coupled with MOD-S
   355   356   357   358   359   360   361   362   363   364   365