          Protection and safety
          OVR Type 2 pluggable QuickSafe® surge protective devices TNS/TT
          230 and 400 V 3Ph+N networks


 Technical features
 Types  OVR T2 3N 40-275 P QS  OVR T2 3N 40-275s P QS  OVR T2 3N 80-275s P  QS  OVR T2 3N 40-350 P QS  OVR T2 3N 40-440 P QS  OVR T2 3N 80-440s P  QS
 with auxiliary contact (TS)  OVR T2 3N 40-275 P TS QS  OVR T2 3N 40-275s P TS QS  OVR T2 3N 80-275s P  TS QS OVR T2 3N 40-350 P TS QS  OVR T2 3N 40-440 P TS QS  OVR T2 3N 40-440s P TS QS  OVR T2 3N 80-440s P TS QS  5
 Technology  Varistor + GDT  Varistor + GDT  Varistor + GDT  Varistor + GDT  Varistor + GDT  Varistor + GDT  Varistor + GDT
 Electrical features
 Standard  IEC 61643-11/EN 61643-11  IEC 61643-11/EN 61643-11  IEC 61643-11/EN 61643-11  IEC 61643-11/EN 61643-11  IEC 61643-11/EN 61643-11  IEC 61643-11/EN 61643-11  IEC 61643-11/EN 61643-11
 Type/test class  T2/II  T2/II  T2/II  T2/II       T2/II               T2/II                T2/II
 Protected lines  3+1  3+1  3+1  3+1               3+1                 3+1                  3+1
 System network  TT - TNS  TT - TNS  TT - TNS  TT - TNS  TT - TNS      TT - TNS             TT - TNS
 Type of current  AC 47-63 Hz  AC 47-63 Hz  AC 47-63 Hz  AC 47-63 Hz  AC 47-63 Hz  AC 47-63 Hz  AC 47-63 Hz
 Voltage regulation of the system network  ± 20 %  ± 20 %  ± 20 %  ± 50 %  ± 10%  ± 10%     ± 10%
 Nominal system voltage Un (L-N/L-L)  [V]  230/400  230/400  230/440  230/400  400/690  400/690  400/690
 Max. cont. operating voltage Uc (L-N/L-L)  [V]  275/440  275/440  275/440   350/600   440/760  440/760  440/760
 Maximum discharge current Imax (8/20)  [kA]  40  40  80  40  40       40                   80
 Maximum impulse current Iimp (10/350)  [kA]  2  2  6.25  2  2         2                    6.25
 Nominal discharge current In (8/20)  [kA]  20  20  20  20  20         20                   20
 Total Current  [kA]  80  80  80  80               80                  80                   80
 Voltage protection level Up at In (L-N/N-PE/L-PE)  [kV]  1.25/1.4/1.5  1.4/1.4/1.5  1.4/1.4/1.5  1.5/1.4/1.7  1.8/1.4/2.1  1.8/2/2.1  1.8/2/2.1
 Voltage protection level Ures at 3kA   [kV]  0.8/1.4/0.85  0.8/1.4/0.85  0.8/1.4/0.85  1.0/1.4/1.05  1.25/1.4/1.45  1.25/1.4/1.45  1.25/1.4/1.45
 (L-N/N-PE /L-PE)
 Voltage protection level Ures at 5kA   [kV]  0.85/1.4/0.95  0.85/1.4/0.95  0.85/1.4/0.95  1.05/1.4/1.1  1.35/1.4/1.45  1.35/1.4/1.45  1.35/1.4/1.45
 (L-N/N-PE /L-PE)
 Voltage protection level Ures at 10kA   [kV]  1/1.4/1.15  1/1.4/1.15  1/1.4/1.15  1.2/1.4/1.3  1.55/1.4/1.65  1.55/1.4/1.65  1.55/1.4/1.65
 (L-N/N-PE /L-PE)
 TOV (Temporary overvoltage) withstand Ut   [V]  337/1200  337/1200  337/1200  455/1200  581/1200  581/1200  581/1200
 (L-N: 5s./N-PE: 200ms)
 Response time  [ns]  < 25  < 25  < 25  < 25       < 25                < 26                 < 25
 Short-circuit withstand capability Isccr  [kA]  100  100  100  100  100  100               100
 Backup protection   fuse (gG)  [A]  ≤ 125  ≤ 160  ≤ 160  ≤ 125  ≤ 125  ≤ 160               ≤ 160
 maximum rating  circuit breaker   [A]  ≤ 125  ≤ 125  ≤ 125  ≤ 125  ≤ 125  ≤ 125            ≤ 125
 (B or C curve)
 Pluggable cartridge  Yes  Yes  Yes  Yes           Yes                 Yes                  Yes
 Integrated QuickSafe® technology  Yes  Yes  Yes  Yes  Yes             Yes                  Yes
 State indicator  Yes  Yes  Yes  Yes               Yes                 Yes                  Yes
 Safety reserve  No  Yes  Yes  No                  No                  Yes                  Yes
 Auxiliary contact  Yes (TS option)  Yes (TS option)  Yes (TS option)  Yes (TS option)  Yes (TS option)  Yes  Yes (TS option)
 Installation
 Wire range (L, N, PE)  solid wire  [mm²]  2.5 … 35  2.5 … 35  2.5 … 35  2.5 … 35  2.5 … 35  2.5 … 35  2.5 … 35
 stranded wire  [mm²]  2.5 … 25  2.5 … 25  2.5 … 25  2.5 … 25  2.5 … 25  2.5 … 25           2.5 … 25
 Stripping length (L, N, PE)  [mm]  12.5  12.5  12.5  12.5  12.5       12.5                 12.5
 Tightening torque (L, N, PE)  [Nm]  2.8  2.8  2.8  2.8  2.8           2.8                  2.8
 Auxiliary contact (TS)
 Contacts information  1 NO - 1 NC  1 NO - 1 NC  1 NO - 1 NC  1 NO - 1 NC  1 NO - 1 NC  1 NO - 1 NC  1 NO - 1 NC
 Min. load  12 DC - 10 mA  12 DC - 10 mA  12 DC - 10 mA  12 DC - 10 mA  12 DC - 10 mA  12 DC - 10 mA  12 DC - 10 mA
 Max. load  250 V AC - 1A  250 V AC - 1A  250 V AC - 1A  250 V AC - 1A  250 V AC - 1A  250 V AC - 1A  250 V AC - 1A
 Connection cross-section  [mm²]  1.5  1.5  1.5  1.5  1.5              1.5                  1.5
 Miscellanous characteristics
 Stocking and operating temperature  [°C]  -40 to +80  -40 to +80  -40 to +80  -40 to +80  -40 to +80  -40 to +80  -40 to +80
 Maximal Altitude  [m]  5000  5000  5000  5000     5000                5000                 5000
 Degree of protection  IP 20  IP 20  IP 20  IP 20  IP 20               IP 20                IP 20
 Fire resistance according to UL 94  V0  V-0  V-0  V0  V0              V-0                  V-0
 Dimensions
 height x width x depth  [mm]  88 x 71.2 x 65.3  88 x 71.2 x 76.7  88 x 71.2 x 76.7  88 x 71.2 x 65.3  88 x 71.2 x 65.3  88 x 71.2 x 76.7
 [inches] 3.46 x 2.8 x 2.57  3.46 x 2.8 x 3.02  3.46 x 2.8 x 3.02  3.46 x 2.8 x 2.57  3.46 x 2.8 x 2.57  3.46 x 2.8 x 3.02
 With Auxiliary Contact (TS)
 height x width x depth  [mm]  95.8 x 71.2 x 65.3  95.8 x 71.2 x 76.7  95.8 x 71.2 x 76.7  95.8 x 71.2 x 65.3  95.8 x 71.2 x 65.3  95.8 x 71.2 x 76.7  95.8 x 71.2 x 76.7
 [inches] 3.77 x 2.8 x 2.57  3.77 x 2.8 x 3.02  3.77 x 2.8 x 3.02  3.77 x 2.8 x 2.57  3.77 x 2.8 x 2.57  3.77 x 2.8 x 3.02  3.77 x 2.8 x 3.02
 Replacement Cartridges
 Phase Product ID  OVR T2 40-275 C QS   OVR T2 40-275s C QS   OVR T2 80-275s C QS   OVR T2 40-350 C QS   OVR T2 40-440 C QS   OVR T2 40-440s C QS   OVR T2 80-440s C QS
 2CTB803876R1000  2CTB815704R2600  2CTB815708R2600  2CTB803886R1000  2CTB803876R0400  2CTB815704R5500  2CTB815708R5500
 Neutral Product ID  OVR T2-T3 N 80-275 C QS   OVR T2 N 80-275s C QS   OVR T2 N 80-275s C QS   OVR T2 N 80-350 C QS   OVR T2-T3 N 80-440 C QS   OVR T2 N 80-440s C QS   OVR T2 N 80-440s C QS
 2CTB803876R0000  2CTB815708R2800  2CTB815708R2800  2CTB803886R0000  2CTB803886R0100  2CTB815708R5700  2CTB815708R5700