P. 280

Semiconductor fuses
                                                   Semiconductor (AC) fuses


                                                                 Protistor Square-body Fuses
                                                                                ®
                                                                   PSC aR sizes 9x - 1500 VAC
                                  Microswitches for other square-body Protistor                                  ®
















             - REMOTE SIGNALING SYSTEMS FOR FITTING ON
              FERRAZ SHAWMUT FUSES EQUIPPED WITH MICROSWITCH SUPPORT:
              all square-body sizes 44 / 8X / 9X / 12X / 17X / 30X and 60X


             - PERMANENT INDICATION OF FUSE STATE
                   • CONDUCTIVE
                   • BLOWN


             - MANUAL RESETTING


             - STANDARD AND LOW ELECTRICAL LEVEL WITH DIFFERENT INSULATION LEVELS

             - VAPOR AND WATERTIGHT MODEL FOR USE IN CORROSIVE ATMOSPHERE


            Main Characteristics



                                             AC or DC AC voltage  Impulse                    Interrupting rating
                                             Insulation  withstand  voltage test  Positive  Current
              Type             Designation    voltage        Uimp1,2/50  operating        Non-inductive  Inductive circuit :
                                              rating   test     µs    min.voltage  rating  Current  circuit  L/R = 25ms
                                               Ui (V)  ( )     (  )  /min.current         30V 110V 250V  30V  110V  250V
                                                        *       **
                               MC3E 1-5N      1250V   15 kV    20 kV    20 V         50/60 Hz 10 A  10 A 7 A   6 A
                Standard                                                        5 A
                               MCR3E 1-5N      2200   20 kV    30 kV    50 mA         DC  5 A 0.5 A       1,6 A  0,3 A
                              MC3E 1-5NBS
                                              1250 V  15 kV    20 kV
                              MC3E 1-9NBS                                            50/60 Hz  3 A 3 A  3 A  2 A  1 A  1 A
                              MCR3E 1-5NBS           20 kV (1)          10 V
                Low level                     2200 V           30 kV            3 A
                              MCR3E 1-9NBS           23 kV (2)          10 mA
                                                                                      DC  3 A 0.5 A 0,25A  3 A  0,2 A  0.1 A
                              MC2R3E 1-5NBS          24 kV (1)
                                              6000 V  26 kV (2)  40 kV
                              MC2R3E 1-9NBS          32 kV (3)
                              MC3E 1-5NET     1250 V  11 kV    16 kV
               Watertight                                               10 V         50 Hz   3 A  3 A     1 A  1 A
                              MCR3E 1-5NET    2200 V  20 kV (1)  30 kV          3 A
                 IP 50                                                  10 mA
                              MC2R3E 1-5NET   6000 V  24 kV (2)  40 kV                DC     0.5 A       0,2 A
             Catalog Numbering system: MC3E 1-5 single pole microswitch - MC3E 1-9 double pole microswitch - MCR, MC2R reinforced insulation
                microswitch.
             *     Between power circuit and microswitch terminals as per IEC 60 and 694 and NFC 64010 (50/60 Hz 1 min duration in dry air).
             **   Between power circuit and microswitch terminals Uimp: impulse voltage according to IEC 947-1.
             *** Between power circuit and microswitch terminals
             (1) fitting sizes 44 - 70 - 71 - 72 - 73 - 83 - 84 fuses.
             (2) fitting sizes 91 - 92 - 93 - 94 -120 - 121 - 122 - 123 - 124 fuses.
             (3) fitting sizes 171 - 172 - 173 - 174 - 300 - 302 - 600 - 602 fuses.










                                                          SCAC156                                              12/04