Page 17 - IDEC relay catalogue
P. 17

Relays & Sockets                                                                     RJ Series



          Socket Specifications
                       Socket              Terminal             Electrical Rating   Wire Size           Torque
                                                                                                       0.6 - 1.0N•m
                       SJ1S-05B  M3 screw with captive wire clamp  250V, 12A   Maximum up to 2 - #14 AWG
         DIN Rail/                                                                                   (Maximum 1.2N•m)
         Panel Mount                                                                                   0.6 - 1.0N•m
                       SJ2S-05B  M3 screw with captive wire clamp  250V, 8A    Maximum up to 2 - #14 AWG               Switches & Pilot Lights
                                                                                                     (Maximum 1.2N•m)
                                                                                                       0.6 - 1.0N•m
                       SJ1S-07L  M3 screw with captive wire clamp, fi ngersafe  250V, 12A  Maximum up to 2 - #14 AWG
                                                                                                     (Maximum 1.2N•m)
         Finger-safe                                                                                   0.6 - 1.0N•m
         DIN Rail/     SJ2S-07L  M3 screw with captive wire clamp, fi ngersafe  250V, 8A  Maximum up to 2 - #14 AWG  (Maximum 1.2N•m)
         Panel Mount
                      SQ1V-07B  M3 screw with box clamp, fi ngersafe  300V, 12A  Maximum up to 2 - #14 AWG  1.0N•m Maximum
                      SQ2V-07B  M3 screw with box clamp, fi ngersafe  300V, 10A  Maximum up to 2 - #14 AWG  1.0N•m Maximum
                       SJ1S-61  PCB mount                         250V, 12A            —                  —
                       SJ2S-61  PCB mount                          250V, 8A            —                  —
         PCB Mount                                                                                                     Display Lights
                       SQ1V-63  PCB mount                         300V, 12A            —                  —
                       SQ2V-63  PCB mount                         300V, 12A            —                  —


          Electrical Life Curve (Resistive Load)
         RJ1                               RJ1 High Capacity                RJ2
          1000                  250V AC     1000                   250V AC     1000

         (× 10,000 operations)  100  30V DC Resistive Load  Resistive Load  (× 10,000 operations)  100  30V DC Resistive Load  Resistive Load  (× 10,000 operations)  100  30V DC Resistive Load  250V AC  Relays & Sockets
                                                                                                    Resistive Load
                                (NO contact)
                                                                   (NO contact)
                                                                                                    (NO contact)
                  (NO Contact)
                                                   (NO Contact)
                                                                                     (NO Contact)
           10
                                             10
                                                                                10
            1                                1                                  1 1
                  0.1    1     12                   0.1   1       16                   0.1   1     8
                 Load Current (A)                   Load Current (A)                   Load Current (A)
        Maximum Switching Capacity (Resistive Load)
         RJ1                               RJ1 High Capacity                RJ2                                        Timers


                    AC Resistive (NO Contact)
                                                          AC Resistive
                                                               AC Inductive           AC Resistive (NO Contact)
           12                                 16                              10 8
          Load Current (A)  1               Load Current (A)  DC Resistive (NC Contact)  DC Resistive  Load Current (A)  1
           10
                                              10
                                                          (NO Contact)
                                                 DC Inductive (NO Contact)
                                              1
                                                      DC Inductive
              DC Resistive (NO Contact)               (NC Contact)
                                                                                  DC Resistive (NO Contact)
          0.1                                0.1                              0.1                                      Terminal Blocks
            1      10     100  250             1     10     100  250            1      10     100  250
                  Load Voltage (V)                   Load Voltage (V)
                                                                                      Load Voltage (V)


















                                            USA: 800-262-IDEC          Canada: 888-317-IDEC                        739  Circuit Breakers
   12   13   14   15   16   17   18   19   20   21   22