Page 27 - IDEC relay catalogue
P. 27
Relays & Sockets RR Series
Hold Down Springs & Clips
For DIN For Through Panel &
Appearance Description Relay Min Order Qty
Mount Socket PCB Mount Socket
RR2P SR2B-02F1
SR3P-01F1
Pullover Wire RR3PA SR3B-02F1 10 pcs Switches & Pilot Lights
Spring
RR1BA, RR2BA, SR3B-02F1 SR3B-02F1
RR3B
Leaf Spring RR2P, RR3PA SFA-203 – 20 pcs
(side latch)
Accessories
Description Appearance Use with Part No. Remarks
IDEC offers a low-profi le DIN rail (BNDN1000). The BNDN1000 is de-
Aluminum signed to accommodate DIN mount sockets. Made of durable extruded Display Lights
DIN Rail All DIN rail sockets BNDN1000 aluminum, the BNDN1000 measures 0.413 (10.5mm) in height and 1.37
(1 meter length)
(35mm) in width (DIN standard). Standard length is 39” (1,000mm).
DIN Rail End DIN rail BNL5 9.1 mm wide.
Stop
Horseshoe clip for sockets Y778-011
Replacement SR3B-05, SR2P-06, SR3P-06 For use on DIN rail mount socket when using pullover wire hold down
Hold-Down
Spring Anchor Chair clip for sockets spring. 2 pieces included with each socket.
SR2P-05(C), SR3P-05(C) Y703-102 Relays & Sockets
Specifications
Contact Material Silver
Contact Resistance 1 30 mΩ maximum
Minimum Applicable Load 1V DC, 10 mA
Operate Time 2 25 ms maximum
Release Time 2 25 ms maximum
AC: 3 VA (50 Hz), 2.5 VA (60 Hz) Timers
Power Consumption (approx.)
DC: 1.5W
Insulation Resistance 100 MΩ minimum (500V DC megger)
Between live and dead parts: 1500V AC, 1 minute
Between contact and coil: 1500V AC, 1 minute
Pin Terminal
Between contacts of different poles: 1500V AC, 1 minute
Dielectric Between contacts of the same pole: 1000V AC, 1 minute
Strength Between live and dead parts: 2000V AC, 1 minute 1. Measured using 5V DC, 1A voltage drop method
Between contact and coil: 2000V AC, 1 minute 2. Measured at the rated voltage (at 20°C), excluding
Blade Terminal contact bouncing Terminal Blocks
Between contacts of different poles: 2000V AC, 1 minute 3. For use under different temperature conditions, refer
to Continuous Load Current vs. Operating Temperature
Between contacts of the same pole: 1000V AC, 1 minute
Curve.
Electrical: 1800 operations/h maximum
Operating Frequency
Mechanical: 18,000 operations/h maximum
Damage limits: 10 to 55 Hz, amplitude 0.5 mm
Vibration Resistance
Operating extremes: 10 to 55 Hz, amplitude 0.5 mm
Damage limits: 1000 m/s (100g)
2
Shock Resistance
Operating extremes: 100 m/s (10G)
2
Mechanical Life 10,000,000 operations Circuit Breakers
Electrical Life 200,000 operations (220V AC, 5A)
Operating Temperature 3 –25 to +40°C (no freezing)
Operating Humidity 5 to 85% RH (no condensation)
Weight (approx.) (Basic type) RR2P: 90g, RR3PA: 96g, RR1BA/RR2BA/RR3B: 82g
USA: 800-262-IDEC Canada: 888-317-IDEC 749