Page 35 - IDEC relay catalogue
P. 35
Relays & Sockets RU Series
Accessories
Description Appearance Use with Part No. Remarks
IDEC offers a low-profi le DIN rail (BNDN1000). The BNDN1000 is de-
Aluminum
DIN Rail All DIN rail sockets BNDN1000 signed to accommodate DIN mount sockets. Made of durable extruded
aluminum, the BNDN1000 measures 0.413 (10.5mm) in height and 1.37
(1 meter length) Switches & Pilot Lights
(35mm) in width (DIN standard). Standard length is 39” (1,000mm).
DIN Rail End DIN rail BNL5 9.1 mm wide.
Stop
Replacement Horseshoe clip for DIN rail For use on DIN rail mount socket when using pullover wire hold down
Hold-Down sockets Y778-011 spring. 2 pieces included with each socket.
Spring Anchor
Coil Ratings Display Lights
Rated Current (mA)
Coil ±15% (at 20°C) Operating Characteristics (values at 20°C)
Rated Voltage (V) Voltage Coil Resistance (Ω)
±10% (at 20°C)
Code 50 Hz 60 Hz Maximum Continuous Pickup Voltage Dropout Voltage
Applied Voltage
24 A24 49.3 42.5 164
AC 110-120 A110 8.4-10.0 7.1-8.2 4,550 110% 80% maximum 30% minimum
(50/60 Hz)
220-240 A220 4.2-5.0 3.6-4.2 18,230
6 D6 155 40
12 D12 80 160 Relays & Sockets
DC 24 D24 44.7 605 110% 80% maximum 10% minimum
48 D48 18 2,560
110 D110 8.9 12,100
1. The rated current includes the current of the LED indicator.
Surge Suppressor Ratings UL and c-UL Ratings
Model Ratings Resistive General Use Horse Power Rating Timers
Voltage
RC series circuit RU2 RU4 RU42 RU2 RU4 RU42 RU2 RU4 RU42
AC Coil With RC
R: 20 kΩ, C: 0.033 μF
250V AC 10A — 3A — 6A — — 1/10HP —
Diode reverse voltage: 1000V
DC Coil With Diode 30V DC 10A 6A 3A — — — — — —
Diode forward current: 1A
CSA Ratings TÜV Ratings
Contact Ratings Resistive Resistive Inductive
Voltage Voltage
Maximum Contact Capacity RU42 RU2 RU4 RU42 RU2 RU4 RU42
Continuous Allowable Contact Power Voltage Rated Load 250V AC 3A 250V AC 10A 6A 3A 5A 0.8A 0.8A Terminal Blocks
Contact
Current Resistive Load Inductive Load (V) Res. Load Ind. Load
30V DC 3A 30V DC 10A 6A 3A 5A 1.5A 1.5A
2500VA AC 1250VA AC 250 AC 10A 5A
DPDT 10A
300W DC 150W DC 30 DC 10A 5A
1500VA AC 600VA AC 250 AC 3A 0.8A
4PDT 6A
180W DC 90W DC 30 DC 3A 1.5A
4PDT 750VA AC 200VA AC 250 AC 3A 0.8A
bifurcated 3A 90W DC 45W DC 30 DC 3A 1.5A
1. On 4PDT relays, the maximum allowable total current of neighboring two poles is 6A. At the rated Circuit Breakers
load, make sure that the total current of neighboring two poles does not exceed 6A (3A + 3A = 6A).
2. Inductive load for the rated load — cos ø = 0.3, L/R = 7 ms
USA: 800-262-IDEC Canada: 888-317-IDEC 757