          High performance


          Robust operation and long lifetime





                                                                                                                       02
                  Robust operation in a wide variety of         Reliability – exceptional mechanical endurance
                  applications                                  The mechanical endurance of OTDC switch-
                  The complete portfolio from 16A to 1000A      disconnectors from 100A up to 1000A is 10 000
                  complies with all the international standards:   mechanical operation cycles, which is up to 90%
                  IEC 60947, UL98B and CCC. Our OTDC S2.0 and   higher than other existing products in the
                  M series fulfill the requirements of AS 60947.3   market.
                  standard. The OTDC range complies with Marine
                  specific DNV GL standard.
                                                                 10 000

                                                                 Operating cycles



                                                                 High thermal capacity
                                                                 When selecting DC switch in different DC
                  OTDC switch-disconnectors from 100A to 800A    applications there are many aspects to consider,
                  fulfill the highest requirements in the IEC    like enclosure size, cable size, type of
                  standards, such as DC-PV2 utilization category.    connection (busbars or lugs) and ambient
                  This means that OTDC can connect and           temperature inside the enclosure. These have an
                  disconnect DC circuits with significant        impact on the thermal capacity of the switch.
                  overcurrents and handle bi-directional current
                  flow.
                                                                 OTDC switch-disconnectors have a high thermal
                  OTDC switch-disconnectors have been tested     capacity, to minimize the derating required in
                  with and without fuses to fulfill higher short   high ambient temperatures. We provide a
                  circuit level requirements. Now OTDC can reach   detailed reference table for the OTDC thermal
                  up to 100kA short-circuit level with fuses.    ratings, based on testing results.

                  IEC standards                                  No derating needed up to
                  DC-PV2                                         75°C

                  ratings                                        in enclosure



                  Short circuit current up to
                  100kA

                  with fuses