          80               ABB  SWITCH-DISCONNECTORS – HIGH PERFORMANCE, COMPACT SOLUTION
          —
          Manual switch-disconnectors OT160...4000, IEC
          Ordering information for earthing switches
                                    —
                                    Front operated earthing switches, bottom mounted (EM), IEC
                                    Including terminal bolt kit, a black OFF -   plastic handle and shaft as standard.
                                    The handle is padlockable in OFF- and   -position.
                                    The mechanism is turned 90 degrees for space saving. Max. number of operations 1200.
          OT1000...1250EM03P
                                    I cw= Rated short-time withstand current, I cm= Rated short-circuit making  capacity
                                                                                                          Weight/
                                    Number   I cw / 1 s    I cw / 0.25 s  I cm peak                          unit
                                    of poles  kA      kA       kA                 Type           Order code   kg
                                    I cw / 1 s = 50 kA, I cm = 110 kA (peak)
                                    3        50       50       110         OT1000EM03P      1SCA118937R1001  17.5
          OT2000...2500EM03P
                                    4        50       50       92          OT1000EM04P      1SCA118950R1001  20.0
                                    3        50       50       110         OT1250EM03P      1SCA115708R1001  17.5
                                    4        50       50       92          OT1250EM04P      1SCA118949R1001  20.0
                                    3        50       50       110         OT1600EM03P      1SCA115815R1001  19.5
                                    4        50       50       92          OT1600EM04P      1SCA118948R1001  22.5
                                    I cw / 1 s = 55 kA, I cw / 0.25 s = 80 kA,  I cm = 176 kA (peak)
                                    3        55       80       176         OT2000EM03P      1SCA118939R1001  42.5
                                    4        55       80       176         OT2000EM04P      1SCA118947R1001  49.5
                                    3        55       80       176         OT2500EM03P      1SCA115835R1001  42.5
                                    4        55       80       176         OT2500EM04P      1SCA118946R1001  49.5
                                    —
                                    Front operated earthing switches with wide phase distance, bottom mounted (EM), IEC
                                    Including terminal bolt kit, a black OFF -   plastic handle and shaft as standard.
                                    The handle is padlockable in OFF- and   -position. W4=140 mm, W8=185 mm.
                                    The mechanism is turned 90 degrees for space saving. Max. number of operations 1200.
                                    Number   I cw /   I cw /   I cm                                       Weight/
                                    of       1 s      0.25 s    peak                                         unit
                                    poles    kA       kA       kA                 Type           Order code   kg
                                    I cw / 1 s = 50 kA, I cm = 110 kA (peak)
                                    3        50       50       110       OT1250EM03W4P      1SCA115805R1001  20.5
                                    3        50       50       110       OT1250EM03W8P      1SCA115810R1001  22.5
                                    4        50       50       92        OT1250EM04W4P      1SCA118940R1001  24.5
                                    4        50       50       92        OT1250EM04W8P      1SCA118941R1001  26.5
                                    3        50       50       110       OT1600EM03W4P      1SCA115822R1001  20.5
                                    3        50       50       110       OT1600EM03W8P      1SCA115827R1001  22.5
                                    4        50       50       92        OT1600EM04W4P      1SCA118942R1001  24.5
                                    4        50       50       92        OT1600EM04W8P      1SCA118944R1001  26.5
                                    I cw / 1 s = 55 kA, I cw / 0.25 s = 80 kA, I cm = 176 kA (peak)
                                    3        55       80       176       OT2500EM03W4P      1SCA115840R1001  45.0
                                    3        55       80       176       OT2500EM03W8P      1SCA115843R1001  47.0
                                    4        55       80       176       OT2500EM04W4P      1SCA118943R1001  52.0
                                    4        55       80       176       OT2500EM04W8P      1SCA118945R1001  54.0