Page 293 - Sace Emax 2 Catalogue
P. 293
ORDERING CODES 10/57
Dedicated terminal for Modified Differential Ground Fault (MDGF) protection
Size Type Code
E1.2..E6.2 MDGF Terminal for fixed circuit breaker (*) 1SDA114800R1
E1.2..E6.2 MDGF Terminal for withdrawable circuit breaker (*) 1SDA114798R1
(*) The commercial code includes one piece.
External phase current transformers and summing current transformers must be purchased separately.
Open/closed auxiliary contacts - AUX
Size Type Code
E1.2 b) AUX 4Q 400V E1.2 1SDA073750R1
E1.2 AUX 4Q 24V E1.2 1SDA073751R1
E1.2 AUX 2Q 400V + 2Q 24V E1.2 1SDA073752R1
E2.2...E6.2 b) AUX 4Q 400V E2.2...E6.2 1SDA073753R1
E2.2...E6.2 AUX 4Q 24V E2.2...E6.2 1SDA073754R1
E2.2...E6.2 AUX 2Q 400V + 2Q 24V E2.2...E6.2 1SDA073755R1
E2.2...E6.2 AUX 6Q 400V E2.2...E6.2 1SDA073756R1
E2.2...E6.2 AUX 6Q 24V E2.2...E6.2 1SDA073757R1
E2.2...E6.2 AUX 3Q 400V AC + 3Q 24V DC E2.2...E6.2 1SDA075973R1
E1.2 a) d) AUX 15Q 400V E1.2 1SDA073758R1
E1.2 a) d) AUX 15Q 24V E1.2 1SDA073759R1
E2.2...E6.2 a) AUX 15Q 400V (for fixed or withdrawable with signaling in 1SDA073760R1
racked in)
E2.2...E6.2 a) AUX 15Q 24V (for fixed or withdrawable with signaling in
racked in) 1SDA073761R1
E2.2...E6.2 a) c) AUX15Q 400V (for withdrawable with signaling in racked in/ 1SDA073846R1
test isolated)
E2.2...E6.2 a) c) AUX15Q 24V (for withdrawable with signaling in racked in/test 1SDA073847R1
isolated)
a) not compatible with mechanical locks on compartment doors or mechanical interlocks.
For E1.2 you need to order also one of the following items:
Plate for fixed - floor mounted 1SDA079783R1
Plate for fixed - wall mounted 1SDA079782R1
Plate for withdrawable 1SDA079784R1
b) Standard supply with automatic circuit-breakers; c) also compatible with fixed version;
d) For E1.2 withdrawable, the AUX 15Q works only in racked-in position
Auxiliary position contacts - AUP
Size Type Code
E1.2 AUP 6 contacts 400V E1.2 1SDA073762R1
E1.2 AUP 6 contacts 24V E1.2 1SDA073763R1
E2.2...E6.2 AUP 5 contacts 400V E2.2...E6.2 - left set 1SDA073764R1
E2.2...E6.2 AUP 5 contacts 24V E2.2...E6.2 - left set 1SDA073765R1
E2.2...E6.2 AUP 5 suppl. contacts 400V E2.2...E6.2 - right set 1SDA073766R1
E2.2...E6.2 AUP 5 suppl. contacts 24V E2.2...E6.2 - right set 1SDA073767R1
E2.2...E6.2 AUP 5 suppl. contacts 400V E2.2...E6.2 - 1in 3test 1out - right set 1SDA082749R1
E1.2...E6.2 AUP Ekip auxiliary position contact E1.2..E6.2 1SDA073768R1
Ready to close signalling contact- RTC
Size Type Code
E1.2 RTC 250V E1.2 1SDA073770R1
E1.2 RTC 24V E1.2 1SDA073771R1
E1.2 RTC Ekip 24V E1.2 1SDA073772R1
E2.2...E6.2 RTC 250V E2.2...E6.2 1SDA073773R1
E2.2...E6.2 RTC 24V E2.2...E6.2 1SDA073774R1
E2.2...E6.2 RTC Ekip 24V E2.2...E6.2 1SDA073775R1
Contact signalling tripping of Ekip protection trip unit - S51
Size Type Code
E1.2 S51 250V E1.2 a) 1SDA073776R1
E1.2 S51 24V E1.2 1SDA073777R1
E2.2...E6.2 S51 250V E2.2...E6.2 a) 1SDA073778R1
E2.2...E6.2 S51 24V E2.2...E6.2 1SDA073779R1
E2.2...E6.2 S51/2 250V 1SDA085699R1
E2.2...E6.2 S51/2 24V 1SDA085700R1 10
a) Standard supply with automatic circuit-breakers.
Terminals for auxiliary connection
Size Type Code
E1.2..E6.2 Terminals 10 pcs 1SDA073906R1
E1.2..E6.2 Terminals 8 pcs INST 1SDA114779R1
E1.2..E6.2 Terminals 18 pcs INST 1SDA114780R1