1/4              SACE EMA X 2 LOW VOLTAGE AIR CIRCUIT-BRE AKERS



          —

          Distinctive features













                           Control                                     Connectivity
                           SACE Emax 2 circuit breaker is the first single de-  SACE Emax 2 series circuit breakers can be inte-
                           vice ready to manage all the dynamics of a   grated perfectly into all automation and energy
                           low-voltage electrical installation.        management systems to improve productivity
                           Managing loads in any condition is now possible   and energy consumption and to carry out remote
                           thanks to Advanced Functionalities such as:  service.
                           •  Load shedding: fast load shedding to guarantee   All circuit breakers can be equipped with commu-
                            continuity for critical loads during black-outs.   nication units for use with Modbus, Profibus, and
                            Typical scenario is when LV distribution is dis-  DeviceNet™ protocols as well as the modern Mod-
                            connected from the grid (MV).              bus TCP, Profinet, EtherNet/IP™ and Open ADR.
                           •  Power controller: patented algorithm to reduce   The cartridge-type modules can be easily installed
                            the peak of power consumed, allowing savings   directly on the terminal box, even at a later date.
                            on electricity bills.                      Furthermore, the integrated IEC61850 communi-
                            Managing different power sources and connect-  cation module enables connection to automation
                            ing them to main grid is also crucial, so that ser-  systems widely used in medium voltage power
                            vice continuity is maaximized.             distribution to create intelligent networks (Smart
                           •  Embedded ATS functions: an automatic transfer   Grids).
                            switch system used in all application where con-  All circuit breaker settings and functions are also
                            tinuity is essential and where there are multi   accessible via Bluetooth, using EPiC mobile app.
                            source supplies.                           This remote connection allows a safer interaction
                           •  Synchrocheck logics: Synchronization of voltage   with the device mitigating the risk of arc flash ac-
                            and frequency to allow plant reconnection to   cidents.
                            the Utility.                               Furthermore with an easy connection thanks to
                            SACE Emax 2 is able to act as a controller of   Ekip Com Hub module, SACE Emax 2 can be inte-
                            Main grid condition, disconnecting a plant when   grated in ABB Ability™ Energy and Asset Manager,
                            necessary and also to adapt protection to on-  exploiting all the capabilities of a cloud comput-
                            grid or off-grid conditions.               ing platform such as predictive maintenance,
                           •  Adaptive protection: Network changes recogni-  analysis and report download.
                            tion and automatic set of thresholds to guaran-  The power and auxiliary connections are opti-
                            tee protection and coordination in on-grid and   mized to simplify connection to the switchgear.
                            off-grid conditions.                       The power terminals, which can be oriented hori-
                                                                       zontally or vertically, have been designed for the
                                                                       most common busbars, while the push-in connec-
                                                                       tions of the auxiliaries ensure immediate and safe
                                                                       wiring.