Page 9 - Sace Emax 2 Manual for design engineers
P. 9

ABB | SACE Emax 2
             Electrical characteristics  Service rated voltage
                                             400 V AC
                                             415 V AC
                                             500 V AC
                                             525 V AC
                                             690 V AC
                                             ______ V AC
                                     Rated uninterrupted current (40°C) (Iu)
                                             100 A                     800 A                     2500 A
                                             200 A                     1000 A                    3200 A
                                             250 A                     1200 A                    4000 A
                                             400 A                     1250 A                    5000 A
                                             600 A                     1600 A                    6000 A
                                             630 A                     2000 A                    6300 A
                                     Ultimate short-circuit breaking capacity (lcu)
                                             42 kA                     120 kA
                                             50 kA                     130 kA
                                             66 kA                     150 kA
                                             85 kA                     200 kA
                                             100 KA                    a ______ V:
                                     Service short-circuit breaking capacity (lcs)
                                             According to the reference standard:______ % of Icu
                                     Admissible rated short-time withstand current (Icw)
                                             Without intentional delay (class A)
                                             With intentional time-delay (category B):
                                             1 s  Icw ______ kA
                                             3 s  Icw ______ kA


                                           NOTE: make sure that the combination of all the electrical values selected is available. Consult
                                               the technical catalog for further details.










































       7 | © 2020 ABB |  1SDH001330R1002 - ECN000134959 - Rev. A           Circuit-breakers E1.2-E2.2-E4.2-E6.2 | 2 - Guide to the product choice