Page 286 - SACE Tmax XT - Catalogue
P. 286

8/58             SACE TMAX XT LOW VOLTAGE MOLDED CASE CIRCUIT-BREAKERS



          —

          Ordering codes for XT5


          Automatic circuit-breakers









                           Distribution circuit-breakers

                           SACE XT5V (200 kA) TMA - Front terminals (F)
                           Size Iu  Trip units  In  Type                    3 poles           4 poles

                                                                            Code              Code
                           XT5 400   TMA      320  XT5V 400 TMA 320-3200
                                              400  XT5V 400 TMA 400-4000
                                              320  XT5V 400 TMA 320-3200  InN=50%
                                              400  XT5V 400 TMA 400-4000  InN=50%  Only available with the Breaking Part
                            XT5 630   TMA     500  XT5V 630 TMA 500-5000               + Trip unit solution
                                              630  XT5V 630 TMA 630-6300
          —
          XT5 - circuit-breaker               500  XT5V 630 TMA 500-5000 InN=50%
                                              630  XT5V 630 TMA 630-6300 InN=50%

                           SACE XT5V (200 kA) Ekip Dip LS/I - Front terminals (F)
                           Size Iu  Trip units  In  Type                    3 poles           4 poles
                                                                            Code              Code
                           XT5 400   Ekip Dip LS/I  250  XT5V 400 Ekip Dip LS/I In=250
                                              320  XT5V 400 Ekip Dip LS/I In=320   Only available with the Breaking Part
                                              400  XT5V 400 Ekip Dip LS/I In=400       + Trip unit solution
                           XT5 630   Ekip Dip LS/I  630  XT5V 630 Ekip Dip LS/I In=630

                           SACE XT5V (200 kA) Ekip Dip LSI - Front terminals (F)
                           Size Iu  Trip units  In  Type                    3 poles           4 poles

                                                                            Code              Code
                           XT5 400   Ekip Dip LSI  250  XT5V 400 Ekip Dip LSI In=250
                                              320  XT5V 400 Ekip Dip LSI In=320   Only available with the Breaking Part
                                              400  XT5V 400 Ekip Dip LSI In=400        + Trip unit solution
                           XT5 630   Ekip Dip LSI  630  XT5V 630 Ekip Dip LSI In=630

                           SACE XT5V (200 kA) Ekip Dip LSIG - Front terminals (F)
                           Size Iu  Trip units  In  Type                    3 poles           4 poles

                                                                            Code              Code
                           XT5 400   Ekip Dip LSIG  250  XT5V 400 Ekip Dip LSIG In=250
                                              320  XT5V 400 Ekip Dip LSIG In=320   Only available with the Breaking Part
                                              400  XT5V 400 Ekip Dip LSIG In=400       + Trip unit solution
                           XT5 630   Ekip Dip LSIG  630  XT5V 630 Ekip Dip LSIG In=630

                           SACE XT5V (200 kA) Ekip Dip LIG - Front terminals (F)
                           Size Iu  Trip units  In  Type                    3 poles           4 poles

                                                                            Code              Code
                           XT5 400   Ekip Dip LIG  250  XT5V 400 Ekip Dip LIG In=250
                                              320  XT5V 400 Ekip Dip LIG In=320   Only available with the Breaking Part
                                              400  XT5V 400 Ekip Dip LIG In=400        + Trip unit solution
                           XT5 630   Ekip Dip LIG  630  XT5V 630 Ekip Dip LIG In=630
   281   282   283   284   285   286   287   288   289   290   291