Voltage Limiting Devices
SDS 3
923 116 SDS 3
Voltage limiting device for a d.c. sparkover voltage of 550 V.
923 116 4013364085978 05 03 01 01 42 g
60,00 €
Type SDS ... 3
Part No. 923 116
VLD type (EN 50122-1) VLD-F
d.c. sparkover voltage (Uag) 550 V +/- 20 %
Impulse sparkover voltage ≤ 1000 V (1 kV/µs)
Lightning current discharge capacity (10/350 µs) 0.1x / 0.5x / 1x 2.5 kA
Lightning current withstand capability (10/350 µs) 25 kA
Short-circuit withstand capability 25 kArms / 100 ms
Operating temperature range (TU) -40 °C ... +80 °C
To be mounted with mast adapter MA SDS M12 or SIEMENS Nr. 8WL6503-xx
SDS 4
923 118 SDS 4
Voltage limiting device for a d.c. sparkover voltage of 230 V.
923 118 4013364104969 05 03 01 01 38 g
60,00 €
Type SDS ... 4
Part No. 923 118
VLD type (EN 50122-1) VLD-F
d.c. sparkover voltage (Uag) 230 V +/- 20%
Impulse sparkover voltage ≤ 650 V (1 kV/µs)
Lightning current discharge capacity (10/350 µs) 0.1x / 0.5x / 1x 2.5 kA
Lightning current withstand capability (10/350 µs) 25 kA
Impulse current discharge capacity (8/20 µs) 0.1x / 0.5x / 1x 20 kA
Safe short-circuit due to welding of the electrodes in case of direct
currents ≥ 600 A / 250 ms
Short-circuit withstand capability 25 kArms / 100 ms; 36 kArms / 75 ms
Long-term current 1 kArms for t ≤ 120 s
Leakage current (Ilc) < 1 µA for 100 V d.c.
Operating temperature range (TU) -40 °C ... +80 °C
To be mounted with mast adapter MA SDS M12 or SIEMENS No. 8WL6503-xx
SDS 5
923 119 SDS 5
Voltage limiting device for a d.c. sparkover voltage of 120 V.
923 119 4013364104976 05 03 01 01 38 g
64,00 €
Type SDS ... 5
Part No. 923 119
VLD type (EN 50122-1) VLD-F
d.c. sparkover voltage (Uag) 120 V +/- 20 %
Impulse sparkover voltage ≤ 600 V (1 kV/µs)
Lightning current discharge capacity (10/350 µs) 0.1x / 0.5x / 1x 2 kA
Lightning current withstand capability (10/350 µs)
25 kA
Voltage Limiting Devices Impulse current discharge capacity (8/20 µs) 0.1x / 0.5x / 1x 20 kA
Safe short-circuit due to welding of the electrodes in case of direct
≥ 600 A / 250 ms
currents
25 kArms / 100 ms; 36 kArms / 75 ms
Short-circuit withstand capability
Long-term current
< 1 µA for 100 V d.c.
Leakage current (Ilc) 1 kArms for t ≤ 120 s
Operating temperature range (TU) -40 °C ... +80 °C
To be mounted with mast adapter MA SDS M12 or SIEMENS No. 8WL6503-xx
Accessories for Voltage Limiting Devices
Mast adapter for SDS Voltage Limiting Devices
723 199 MA SDS M12
For installation on the mast profile of overhead contact line masts with Ø8-12 mm.
723 199 4013364151703 05 03 01 01 750 g
180,00 €
Type MA SDS M12
Part No. 723 199
Lightning current carrying capability (10/350 µs) 25 kA
Short-circuit withstand capability 21 kArms / 30 ms
Long-term current 1 kArms at t ≤ 120 s
Leakage current (Ilc) < 1 µA at 100 V d.c.
Dimensions of the threaded pin M12
Material Brass
Degree of protection of the inner enclosure IP 67