AFDD - DS-ARC1M
         COMMERCIAL AND INDUSTRIAL RANGE


                                                  10kA  ARC FAULT DETECTION DEVICE (AFDD) WITH
        Features and Ratings:                     INTEGRATED RCBO                                                 DIN MCB &
        - Complete protection against arc faults overvoltages,                                                   LOADCENTRES
           overcurrent, earth fault currents.        Current Rating (A)                         C Curve
                                                   RCBO Type A 30mA
        - 1P+N: 10kA @ 230VAC to IEC/EN 61009-2-1         10                                    DS-ARC1MC10A30
                                                          16                                    DS-ARC1MC16A30
                                                          20                                    DS-ARC1MC20A30















                     DS-ARC1M...




        Every year in Australia there are over 10,000 house fires, resulting in death, injury, and millions of dollars’ worth of property damage. Even a minor electrical fault can have
        serious consequences.



        Arc faults can be in Series, Parrallel or to Earth.  If the arc current is below the tripping threshold of the upstream MCB or RCD, there is a significant risk of fire.  Plus these
        devices may not trip at all depending on the type of arc fault. However an AFDD will detect any type of arc current and trip to clear the fault, protecting the installtion.



        The most frequent causes of arc faults are:
        • Damaged insulation by screws or nails.                  Series
        • Trapped cables in doors and windows.                    Arc fault ≥5A    L
        • Incorrect installation.
        • Cable breakage.                                                                      Load
        • UV radiation and rodent damage to cables in the outdoor areas.
        • Loose contacts and connections.                                          N
        • Snapped plugs and cables.
                                                                  Parallel
                                                                  arc fault ≥75A   L

                                                                                               Load

                                                                                   N


                                                                  Earth arc fault
                                                                                   L
                                                                                               Load


                                                                                   N