Page 229 - dehn-catalogue-lightning-protection_3
P. 229
Round Wires, Strips, Cables
Round Wires
According to EN 62561-2, for use in lightning protection and earth-termination systems.
Stainless steel wire 860 908 860 920 860 950 860 910 860 008 RD 8 V2A R125M
RD 10 V2A R20M
RD 10 V2A R50M
RD 10 V2A R80M
RD 8 V4A R125M
RD 10 V4A R20M
860 050 860 010 860 020 RD 10 V4A R80M
RD 10 V4A R50M
Stainless steel wires (Rd 10 mm) for use in soil have to be made of StSt (V4A) with a molybdenum content > 2 %, e.g. 1.4571 or 1.4404, in
accordance with EN 62561-2, IEC/EN 62305-3, DIN 18014 and DIN VDE 0151. 860 908 125 860 920 m 4013364019362 02 01 01 03 395.00 g/m 617.00 g/m
11,64 €
4013364092679 02 01 01 03
860 950 20 m 19,36 € 4013364155596 02 01 01 03 617.00 g/m
50 m 18,23 €
860 910 4013364019300 02 01 01 03 617.00 g/m
80 m 18,23 €
860 008 4013364018808 02 01 01 03 395.00 g/m
125 860 010 80 m m 17,00 € 4013364019997 02 01 01 03 617.00 g/m
26,57 €
General technical data: 860 020 20 860 050 50 m m 4013364092662 02 01 01 03 617.00 g/m 617.00 g/m Conductor material
27,81 €
4013364139923 02 01 01 03
26,57 €
Standard based on EN 62561-2
Part No. 860 908 860 920 860 950 860 910 1
Diameter Ø conductor 8 mm 10 mm 10 mm 10 mm
Cross-section 50 mm 2 78 mm 2 78 mm 2 78 mm 2
Material StSt StSt StSt StSt
Material No. 1.4301 / 1.4303 1.4301 / 1.4303 1.4301 / 1.4303 1.4301 / 1.4303
Short-circuit current (50 Hz) (1 s; ≤ 300 °C) — — — —
Coil weight approx. 50 kg approx. 12 kg approx. 31 kg approx. 50 kg
PU 125 m 20 m 50 m 80 m
Part No. 860 008 860 010 860 020 860 050
Diameter Ø conductor 8 mm 10 mm 10 mm 10 mm
Cross-section 50 mm 2 78 mm 2 78 mm 2 78 mm 2
Material StSt (V4A) StSt (V4A) StSt (V4A) StSt (V4A)
Material No. 1.4571 / 1.4404 1.4571 / 1.4404 1.4571 / 1.4404 1.4571 / 1.4404
Short-circuit current (50 Hz) (1 s; ≤ 300 °C) — 2.9 kA 2.9 kA 2.9 kA
Coil weight approx. 50 kg approx. 50 kg approx. 12 kg approx. 31 kg
PU 125 m 80 m 20 m 50 m
Steel wire 800 008 800 010 800 310 RD 8 STTZN R127M
RD 10 STTZN R81M
RD 10 STTZN R30M
2
With zinc coating ≥ 50 µm on average (approx. 350 g/m ).
800 008 127 800 010 m 4013364018716 02 01 01 01 394.00 g/m 617.00 g/m
3,81 €
4013364018723 02 01 01 01
Part No. 800 008 800 010 800 310 81 800 310 30 m m 5,67 € 4013364131064 02 01 01 01 617.00 g/m
5,87 €
Diameter Ø conductor 8 mm 10 mm 10 mm
Cross-section 50 mm 2 78 mm 2 78 mm 2
Material St/tZn St/tZn St/tZn
Standard based on EN 62561-2 based on EN 62561-2 based on EN 62561-2
Short-circuit current (50 Hz) (1 s; ≤ 300 °C) — 5.5 kA 5.5 kA
Coil weight approx. 50 kg approx. 50 kg approx. 18.5 kg
PU 127 m 81 m 30 m
Steel wire, straightened, cut into bars 800 910 800 911 RD 10 STTZN L3000
RD 10 STTZN L6000
With zinc coating ≥ 50 µm on average (about 350 g/m ). Suitable for installation in reinforcements (e.g. concrete supports).
2
800 910 pc(s) 19,26 € 4013364253315 02 01 01 01 1.85 kg 10
800 911
4013364273689 02 01 01 01
Part No. 800 910 800 911 1 pc(s) 38,11 €
4.10 kg/Stk
Diameter Ø conductor 10 mm 10 mm
Cross-section 78 mm 2 78 mm 2
Material St/tZn St/tZn
Standard based on EN 62561-2 based on EN 62561-2
Short-circuit current (50 Hz) (1 s; ≤ 300 °C) 5.5 kA 5.5 kA
Length 3 m 6 m
PU 10 pc(s) 1 pc(s)
Steel wire with plastic sheath 800 108 800 110 RD 8 KM STTZN R75M
RD 10 KM STTZN R50M
With plastic sheath as additional mechanical / corrosion protection, e.g. when connected to the lightning protection system.
Suitable for installation on, in and under plaster, mortar or concrete. 800 108 75 800 110 50 m m 4013364018754 02 01 01 01 440.00 g/m 680.00 g/m
6,18 €
4013364018761 02 01 01 01
8,65 €
Part No. 800 108 800 110
Diameter Ø conductor 8 mm 10 mm
Cross-section 50 mm 2 78 mm 2
Material St/tZn St/tZn
Standard based on EN 62561-2 based on EN 62561-2
Outside diameter Ø 11 mm 13 mm
Material of sheath plastic plastic
Sheath thickness 1.5 mm 1.5 mm
Coil weight approx. 33 kg approx. 34 kg
PU 75 m 50 m
Valid as of March 1, 2020 Detailed product information can be found on our website 225