Page 66 - dehn-catalogue-safety-equipment_0
P. 66

Fixed Phase and Earthing Points  EaS Cables  Phase Connecting Elements  Earth Connecting Elements  Earthing Sticks  EaS Devices, Short-Circuiting Bars
        4. Carry out Earthing and Short-Circuiting – EaS Devices


        Earthing and Short-Circuiting Cables, unequipped
                                                             •  To be equipped with connecting components
                                                             •  Transparent sheath
                                                             •  Waterproof and plastic-sheathed cable entries and node unit,
                                                               additional anti-kink protection
                                                             •  Standard anti-rotation crimped cable lugs (type PK1)
                                                             •  Other cable lengths and crimped cable lugs can be selected
                                                               online via the earthing and short-circuiting configurator
                                                             •  Earthing and short-circuiting devices can be configured online
                                                               via the earthing and short-circuiting configurator





        Equipped three-pole earthing and short-circuiting device in a switchgear instal-  General Information:
        lation                                               Standard                 EN/IEC 61138 (DIN VDE 0283-3) and
                                                                                      EN/IEC 61230 (DIN VDE 0683-100)
                                                             Temperature range        – 25 °C ... +55 °C
                                                                                      Al, flexible; E-Cu, extra finely stranded
                                                             Material (cable)
                                                                                      and highly flexible
                                                                                      Thermoplastic polymer
                                                             Material (sheath)
                                                                                      (flexible PVC compound YM2)
                                                             Hole (cable lug)         Ø12.5 mm



               EaS Configurator:
              www.dehn.de/en/euk




                                  Crimped cable lugs, type PK1:  Crimped cable lugs, type PK2:  Crimped cable lugs, type PK3:
                                  Standard anti-rotation cable lug with   Cable  lugs  without  cut-out  for  con-  Hook-type  cable  lugs  up  to  cable
                                  cut-out.                   necting parts from other manufactur-  cross-sections of 35 mm 2  are availa-
                                                             ers are available on request.  ble on request.






                         Single-pole Earthing and Short-circuiting Cables, aluminium version

                                                                A = 5000 mm
        VGHVBP5   EKV1+0 35 VGHVBP5
        VKVBG8W   EKV1+0 50 VKVBG8W
        VVXDACJ   EKV1+0 70 VVXDACJ
        VGHVBP5   4013364360389  05 00 04 05      1.12
        kg         0,00 €
        VKVBG8W   4013364360136  05 00 04 05      1.51
        kg         0,00 €
        VVXDACJ   4013364279032  05 00 04 03      1.94
        kg         0,00 €
                          Type                        EKV1+0 35 VGHVBP5  EKV1+0 50 VKVBG8W  EKV1+0 70 VVXDACJ
                          Variant No.                 VGHVBP5            VKVBG8W            VVXDACJ
                          Cable cross-section         35 mm 2            50 mm 2            70 mm 2
                          Material                    Al                 Al                 Al
                          Max. short-circuit current Ik 0.5 s  6.5 kA    9.3 kA             13.0 kA
                          Max. short-circuit current Ik 1 s  4.6 kA      6.6 kA             9.2 kA
                          Crimped cable lug           PK1                PK1                PK1
                         Attention: Please state the relevant Variant No. when ordering.
    4. EaS Devices
















        64               You will find detailed product information on our website            Valid as of January 1, 2019

    EaS Devices 4.
   61   62   63   64   65   66   67   68   69   70   71