Fixed Phase and Earthing Points  EaS Cables  Phase Connecting Elements  Earth Connecting Elements  Earthing Sticks  EaS Devices, Short-Circuiting Bars
           4. Carry out Earthing and Short-Circuiting – EaS Devices

           Kit for Supply Lines, Line Feeders, Bypass Lines and other Types of Lines                        750 213   BEV SVUL
           For earthing the supply line and traction current lines
           Telescopic earthing stick with adjusting ring (max. 3.5 m long).                                 750 213  kg      4013364123861  05 00 04 06      8.76

                                                                                                              0,00 €
             3
                                                        9                                        Kit includes:
                                                                              6             Type   Part No.  Pos. No.
                                                                                         EKV LK 50 4000  1x 750 042  3+6+9
                                                                                        ESTC SQL RW 3500 1x 769 352  15
            15


           Type BEV ...                SVUL
           Part No.                    750 213
           Cable cross-section         50 mm 2
           Cable length                4000 mm
           Max. short-circuit current Ik 0.06 s  34.0 kA
           DB drawing No.              3 Ebgw 01.57
           DB material No.             237 119




           Kit for Electric Point and Train Pre-Heating Systems                                             750 215   BEV WHA ZVA
           For the initial equipment of a transformer of electric point and train pre-heating systems.
                                                                                                            750 215   4013364123878  05 00 04 06      7.30
                                                                                                            kg         0,00 €
                                   18



                                                10
                                                                                                 Kit includes:
                                                                                            Type   Part No.  Pos. No.
                                                                                        EKV2 50 KKH 600 1800 2x 751 150  10
                                                                                          ES SK 1500  1x 761 015  16
                                                                                          HV EKV ES30  1x 700 000  18
                                                16






           Type BEV ...                WHA ZVA
           Part No.                    750 215
           Cable cross-section         50 mm 2
           Cable length                600 / 1800 mm
           Max. short-circuit current Ik 0.06 s  34.0 kA
           DB drawing No.              3 Ebgw 01.70
           DB material No.             742 402
           For voltage detectors for electric point heating systems, please refer to the PHE voltage detector chapter.