ADVANCED ENERGY METER
SMART TOU ADVANCED ENERGY METER FOR COMMERCIAL AND RESIDENTIAL APPLICATIONS, NMI APPROVED WITH NITP
14 VERIFICATION
SMART TOU ADVANCED ENERGY METER is a Smart Multifunction DIN Rail mounted, Tariff (TOU) Energy Meter designed for Revenue Billing,
Energy Management, NABERS/Green Star and approved by National Measurement Institute (NMI) for use as an electricity meter.
Description Part No.
CT connect 3 phase meter IPDEM133-CT
100A Direct connect 3 phase meter IPDEM133-DC
Features:
Multifunctional 3-Phase or 3-Single Phase Smart Meter
(Meters can measure single phase as well)
- True RMS, volts, amps, power, power factor, neutral current,
voltage and current unbalance, frequency.
- Neutral Current Calculation.
- Ampere/Volt demand meter.
- 50 Hz measurements.
-128 samples per cycle.
Billing/TOU Energy Meter
- Accuracy Class 0.5S.
- Four-quadrant active and reactive energy poly-phase static meter.
- Three-phase total and per phase energy measurements; active,
reactive and apparent energy counters.
- Time-of-Use, 8 totalization and tariff energy/demand registers
x 8 tariffs, 4 seasons x 4 types of days, 8 tariff changes per day. Display
- One–time easy programmable tariff calendar schedule. - Easy to read 2 x 16 Characters LCD display, adjustable update time.
- Automatic daily energy and maximum demand profile log for - Auto-scroll option with adjustable page exposition time;
total and tariff registers. auto-return to a default page.
- Display and communicate this period, last period and previous period
for daily, weekly, monthly and quarterly consumption. Real-time Clock
- Cost calculation (upon application). - With backup battery.
- CO2 (upon application).
Inputs/Outputs
Water and Gas Measurement - Built-in 2 Digital Inputs and 1 form A solid state digital output.
- Direct connection to pulse output water and gas meters. - Optional module 4 Digital Inputs and 2 digital outputs
- Setting of multiplication factors and units. (Solid State or Electro Mechanical).
- Display of consumption in real values. - Optional module 4 Analog Outputs.
- Optional module 12 Digital Inputs and 4 digital outputs
Harmonic Analyser (+ Ethernet or RS485).
- Voltage and current THD, TDD and K-Factor, up to 40th order harmonic.
- Voltage and current harmonic spectrum and angles. Communications
- Standard 2-wire RS-485 communication port .
Real-time Waveform Capture (via PC) - Built-in IR communication port.
- Real-time “scope mode” waveform monitoring. - Optional multipurpose RS-232/422/485 port.
- Simultaneous 6-channel 8-cycle waveform capture at a rate of 64 samples per cycle. - Optional 10/100Base T port.
- Optional RF module (available in certain regions only).
Programmable Logical Controller - Optional GPRS modem.
- Embedded programmable controller.
- 16 control set points; programmable thresholds and delays. Communication Protocols
- Relay output control. - Modbus RTU.
- 1-cycle response time. - Modbus TCP/IP.
Event and Data Recording Meter Security
- Non-volatile memory for long-term event and data recording for - 3 levels Password security for protecting meter setups
at least 45 days history storage capabilities in 15 minute intervals. and accumulated data from unauthorized changes.
- Event recorder for logging internal diagnostic events and setup changes.
- Two data recorders; programmable data logs on a periodic Upgradeable Firmware
basis; automatic daily energy and maximum demand profile log. - Easy upgrading device firmware through a serial or Ethernet port.
35 Photovoltaic Catalogue v-19 www.ipd.com.au Phone: 1300 556 601