Page 34 - photovoltaic-2019-V19
P. 34

ADVANCED ENERGY METER






       SMART TOU ADVANCED ENERGY METER FOR COMMERCIAL AND RESIDENTIAL APPLICATIONS,  NMI APPROVED WITH NITP
       14 VERIFICATION

       SMART TOU ADVANCED ENERGY METER is a Smart Multifunction DIN Rail mounted, Tariff (TOU) Energy Meter designed for Revenue Billing,
       Energy Management, NABERS/Green Star and approved by National Measurement Institute (NMI)  for use as an electricity meter.





       Description                                    Part No.
       CT connect 3 phase meter                   IPDEM133-CT
       100A Direct connect 3 phase meter          IPDEM133-DC


       Features:
       Multifunctional 3-Phase or 3-Single Phase Smart Meter
       (Meters can measure single phase as well)
       - True RMS, volts, amps, power, power factor, neutral current,
          voltage and current unbalance, frequency.
       - Neutral Current Calculation.
       - Ampere/Volt demand meter.
       - 50 Hz measurements.
       -128 samples per cycle.

       Billing/TOU Energy Meter
       - Accuracy Class 0.5S.
       - Four-quadrant active and reactive energy poly-phase static meter.
       - Three-phase total and per phase energy measurements; active,
         reactive and apparent energy counters.
       - Time-of-Use, 8 totalization and tariff energy/demand registers
          x 8 tariffs, 4 seasons x 4 types of days, 8 tariff changes per day.  Display
       - One–time easy programmable tariff calendar schedule.       - Easy to read 2 x 16 Characters LCD display, adjustable update time.
       - Automatic daily energy and maximum demand profile log for     - Auto-scroll option with adjustable page exposition time;
         total and tariff registers.                                  auto-return to a default page.
       - Display and communicate this period, last period and previous period
         for daily, weekly, monthly and quarterly consumption.      Real-time Clock
       -  Cost calculation (upon application).                      - With backup battery.
       -  CO2 (upon application).
                                                                    Inputs/Outputs
       Water and Gas Measurement                                    - Built-in 2 Digital Inputs and 1 form A solid state digital output.
       - Direct connection to pulse output water and gas meters.    - Optional module 4 Digital Inputs and 2 digital outputs
       - Setting of multiplication factors and units.                 (Solid State or Electro Mechanical).
       - Display of consumption in real values.                     - Optional module 4 Analog Outputs.
                                                                    - Optional module 12 Digital Inputs and 4 digital outputs
       Harmonic Analyser                                              (+ Ethernet or RS485).
       - Voltage and current THD, TDD and K-Factor, up to 40th order harmonic.
       - Voltage and current harmonic spectrum and angles.          Communications
                                                                    - Standard 2-wire RS-485 communication port .
       Real-time Waveform Capture (via PC)                          - Built-in IR communication port.
       - Real-time “scope mode” waveform monitoring.                - Optional multipurpose RS-232/422/485 port.
       - Simultaneous 6-channel 8-cycle waveform capture at a rate of 64 samples per cycle.   - Optional 10/100Base T port.
                                                                    - Optional RF module (available in certain regions only).
       Programmable Logical Controller                              - Optional GPRS modem.
       - Embedded programmable controller.
       - 16 control set points; programmable thresholds and delays.  Communication Protocols
       - Relay output control.                                      - Modbus RTU.
       - 1-cycle response time.                                     - Modbus TCP/IP.

       Event and Data Recording                                     Meter Security
       - Non-volatile memory for long-term event and data recording for    - 3 levels Password security for protecting meter setups
         at least 45 days history storage capabilities in 15 minute intervals.    and accumulated data from unauthorized changes.
       - Event recorder for logging internal diagnostic events and setup changes.
       - Two data recorders; programmable data logs on a periodic   Upgradeable Firmware
          basis; automatic daily energy and maximum demand profile log.  - Easy upgrading device firmware through a serial or Ethernet port.




    35  Photovoltaic Catalogue v-19                    www.ipd.com.au                            Phone: 1300 556 601
   29   30   31   32   33   34   35   36