Page 170 - Product-catalogue-v17
P. 170

Fuses & Fittings



        MV FUSE LINKS


                                               MV DIN PROTECTION FUSES - OUTDOOR 6 - 12kV
        Features:                                             Minimum       Barrel
           - Back-Up Protection 6kV to 12kV    Rated          Breaking      Diameter    Length = a   Part No.
           - Suitable for indoor or outdoor switchgear.  Current  (A)  Current (A)  (mm)  (mm)
          Breaking capacity 63kA               1.0            14                                     45DB120V1P
           - Complies to IEC60282-1            2.0            16                                     45DB120V2P
           - Medium trip indicators
                                               4.0            22                                     45DB120V4P
                                               6.3            30                                     45DB120V6.3P
                                               10             42                                     45DB120V10P
                                               16             54                                     45DB120V16P
                                                                            56
                                               20             73                                     45DB120V20P
                                               25             93                        292          45DB120V25P
                                               31.5           105                                    45DB120V31.5P
                     45DB120V80P
                                               40             125                                    45DB120V40P
                                               50             160                                    45DB120V50P
        Definition:
           - Back-up fuse links have a rated minimum  63      230                                    45DB120V63P
            breaking current from which the fuse links are     80  350      65                       45DB120V80P
            able to interrupt current          100            500           78                       45DB120V100P
           - Back-up fuse links are not supposed to operate   160  560                               45DB120V160P
            below their minimum breaking current                            88
                                               200            610                                    45DB120V200P




                                               MV DIN PROTECTION FUSES - OUTDOOR 10 - 24kV
        Features:                                             Minimum       Barrel
           - Back-Up Protection 10kV to 24kV   Rated          Breaking      Diameter    Length = a   Part No.
           - Suitable for indoor or outdoor switchgear  Current  (A)  Current (A)  (mm)  (mm)
           - Breaking capacity up to 63kA      1.0            14                                     45DB240V1P
           - Complies to IEC60282-1            2.0            16                                     45DB240V2P
           - Medium trip indicators
                                               4.0            23                                     45DB240V4P
                                               6.3            30                                     45DB240V6.3P
                                               10             43                                     45DB240V10P
                                               16             60            56                       45DB240V16P
                                               20             76                                     45DB240V20P
                                               25             93                        442          45DB240V25P
                                               31.5           105                                    45DB240V31.5P
                                               40             130                                    45DB240V40P
                     45DB240V25P               50             205                                    45DB240V50P
                                               80             310           65                       45DB240V80P
                                               100            430           78                       45DB240V100P
                                               125            760                                    45DB240V125P (1)
                                               160            900           88                       45DB240V160P (1)
                                               200            1050                                   45DB240V200P (1)
                                               (1)   31.5kA breaking capacity.


                                               Description                                           Part No.
                                               Fuse clips with retaining spring. suit 45mm Ø diameter  HVDCC








                       HVDCC







          170                                    1300 556 601  |  ipd.com.au  |  V17-R04
   165   166   167   168   169   170   171   172   173   174   175