Variable Speed Drives
ACQ80 SOLAR PUMP DRIVE
ACQ80 WALL MOUNT DRIVES - 30KW TO 200KW - IP55
Features:
- Maximum Power Point Tracking (MPPT) logic Nominal Ratings Frame
- Built-in process PID controller Output Current (A) Typical Motor Power (kW) Size Model Part No.
- EMC C2 filter allows safe installation in first
environment Rated Supply Voltage AC (V): 380 - 480, three phases
- Modbus RTU RS-485 communication Rated Supply Voltage DC (V): Frames R4 - R5, 300 - 800V DC
- Integrated Safe Torque Off (STO) function Rated Supply Voltage DC (V): Frames R6 - R9, 390 - 800V DC1
- Compliance with the highest safety 62 30 R4 ACQ80-01-030KW-4 3AXD50001028985
performance level (SIL 3/Pl e)
- Bluetooth Control panel with graphical display 73 37 R4 ACQ80-01-037KW-4 3AXD50001028992
- Dry clean air-cooling method 89 45 R4 ACQ80-01-045KW-4 3AXD50001029005
106 55 R5 ACQ80-01-055KW-4 3AXD50001029111
145 75 R6 ACQ80-01-075KW-4 3AXD50001195809
169 90 R7 ACQ80-01-090KW-4 3AXD50001195915
206 110 R7 ACQ80-01-110KW-4 3AXD50001195922
246 132 R8 ACQ80-01-132KW-4 3AXD50001195939
293 160 R8 ACQ80-01-160KW-4 3AXD50001195946
363 200 R9 ACQ80-01-200KW-4 3AXD50001195953
+ B056 = Drives with IP55 protection
+ J429 = ACS-AP-W assistant control panel with a Bluetooth interface
1 If ACQ80-01 frames R6-R9 (75 to 200 kW) are expected to start only by DC source from the PV cells
or are expected to operate on Intelligent Hybrid mode, it is essential to incorporate an external pre-
charging circuit on the DC bus. The existing built-in Pre-charging Circuit into ACQ80-01 for frames
(R6-R9) can be used if the drives are started only on the AC supply. Detailed specifications and
installation guidelines for the pre-charging circuit can be found in the hardware manual.
DIMENSIONS AND WEIGHTS
Frame H W D Weight
Size (mm) (mm) (mm) (kg)
R4 636 203 265 23.3
R5 732 203 320 33
R6 727 252 380 43
R7 880 284 381 56
H
R8 965 300 452 77
R9 955 380 477 103
D
W
696 1300 556 601 | ipd.com.au | V17-R12