Page 725 - IPD Product Catalog V17
P. 725

Safety Automation & Control



        SAFETY RELAYS


                                             SINGLE AND DUAL CHANNEL SAFETY RELAYS
        Features:                             Rated Control
           - Degree of protection: IP20       Voltage (V)  Timer Function  Contacts        Type         Part No.
           - Complies with standards ISO 13849            No               3NO + 1NC       2TLA010040R0000 BSR10
           - Continuous operation                         No               4NO             2TLA010040R0200 BSR11
           - Optimized logistics              24 DC
           - Easy to install                              No               4NO + 1NC       2TLA010041R0600  BSR23
           - DIN Rail mounted                             Off-delay 0.5s & 1.5s  3NO + 1NC  2TLA010061R0000  TSR20
           - All models have auto reset                   Off-delay 0.5s & 1.5s   3NO + 1NC  2TLA010060R0000 TSR10
                                                          Advanced 0 - 999s
                                                                           2NO + 2NO
                                                          Off-delay 0.5s                   2TLA010052R0400 SSR32
                                                                           (Delayed/Delayable)
                                              24 DC                        2NO + 2NO
                                                          Off-delay 1.5s                   2TLA010053R0400 SSR42
                                                                           (Delayed/Delayable)
                                                          No               3NO + 1NC       2TLA010050R0000 SSR10
                                                          No               3NO + 1NC       2TLA010051R0000  SSR20
                                              120 - 375 DC /   No          3NO + 1NC       2TLA010051R0100  SSR10M
                                              85 - 265 AC  No              3NO + 1NC       2TLA010050R0100  SSR20M
                                                          Off-delay 0.5s & 1.5s
                                                          Advanced 0 - 999s  3NO + 1NC     2TLA010070R0000 USR10
                 SSR10M     SSR20M            24 DC
                                                          No               2NO + 2NO       2TLA010070R0400 USR22
                                                                           (Delayed/Delayable)
                                             -  For additional options please contact IPD customer service.



                                             VITAL SAFETY CONTROLLER SYSTEM
        Features:                             Maximum DYNlink
           - DYNLink Safety Controller        Devices         Rated Voltage (V)  Safe Outputs  Type     Part No.
           - Reduces the wiring points        30              24 DC          2NO           2TLA020052R1000 VITAL1.24D
           - Advanced diagnostics
           - Easily scalable
           - Connect up to 30 Dynamic Pulse devices to one
          Vital Controller
           - Cannot be bypassed at the controller
           - Flashing Lights guide you to the problem
           - Tina adaptors convert dual channel devices to
          Dynamic Pulse
                                                                                                                    6












                      VITAL1.24D




















                                               1300 556 601  |  ipd.com.au  |  V17-R05                       725
   720   721   722   723   724   725   726   727   728   729   730