Page 27 - 1000V Product Range
P. 27

AF CONTACTOR


        OVERLOADS


                                         Electronic Overloads
           Features:
                                                                                    Current setting
           •  Manual or automatic reset   To Suit             Separate mounting kit                  Part No.
                                                                               A (Min.)   A (Max.)
            selectable
           •  TEST and STOP function – Trip                                    20         56         EF65-56
                                         AF40, AF52, AF65     DB65
            indication on the front                                            25         70         EF65-70
           •  High accuracy                                                    20         56         EF96-56
           •  Temperature compensation   AF80, AF96           DB96
                                                                               36         100        EF96-100
           •  Trip contact (N.C.), signal contact
                                         AF116, AF140, AF146                   54         150        EF146-150
            (N.O.),
                                         AF145, AF185, AF190, AF205            63         210        EF205
           •  Tripping class 10E, 20E, 30E
                                         AF210, AF260, AF300, AF305,
                                                                               115        380        EF370
                                         AF370                Not required
                                         AF400, AF460                          150        500        EF460-500
                                         AF580, AF750                          250        800        EF750-800
                                         •  The EOL can be used with any contactors by wiring (EF65 and EF96 requires separate
                                          mounting kit)
                                         •  Auxiliary circuit is up to 600 V AC/DC


                       EF65








        SAFETY


        CONTACTORS


                                         35 TO 75kW

                                         3 Pole – 3NO Safety Contactors - AC/DC Operated
  To complete Part Number, add the required voltage code:
 Code  11  12  Features:                                                              Auxiliary
        •  AC/DC Operated.               1000V AC-3 (kW)    1000V AC-3 (A)                           Part No.
 Control Voltages  24-60 V AC/DC  48-130 V AC/DC                               NO         NC
        •  Safety with AF technology.
        •  Front-mounted auxiliary contact block   35       25                 2          2          AFS803022
 Code  13  14  (Yellow-Permanently fixed.).  40             30                 2          2          AFS963022
 Control Voltages  100-250 V AC/DC  250-500 V AC/DC  •  The built-in auxiliary contact elements
          are mechanically linked (side-marked
 * To complete Part Number, add the required voltage code:  symbol) and the N.C. auxiliary contacts    To complete Part Number, add the required voltage code:
          are mirror contacts.           Code                    11                      13
  Code  70
        •  Reduced panel energy consumption.  Voltages V AC/DC   24...60                 100…250
 Control Voltages  100-250 V AC/DC
        •  For connection with built-in
          cable clamps.                  •  Version with built in PLC interface is available, please contact IPD.
        •  Din or Panel mount.









           AFS093022...      AFS963022...







                                                                                                1000V Products | 27