          Direct-on-line starters protected by thermal overload relays
          With AF contactors - Open type version in kit form




                    Contactors                                 Thermal overload relays               Accessories








          IEC       Control voltage   Type  Order code         Setting ranges Type  Order code
          AC-3, 400 V  Uc min. ... Uc max.
          Rated   Rated    (1)
          power  current
          kW   A    V 50/60 Hz  V DC (2)                       A
          4    8.5  24...60   20...60  AF09Z-30-10-21  1SBL136001R2110  7.60...10.0  TF42-10  1SAZ711201R1043
                    100...250  100...250  AF09-30-10-13  1SBL137001R1310
          5.5  11.5  24...60   20...60  AF12Z-30-10-21  1SBL156001R2110  10.0...13.0  TF42-13  1SAZ711201R1045
                    100...250  100...250  AF12-30-10-13  1SBL157001R1310
          7.5  15.5  24...60   20...60  AF16Z-30-10-21  1SBL176001R2110  13.0...16.0  TF42-16  1SAZ711201R1047
                    100...250  100...250  AF16-30-10-13  1SBL177001R1310
          11   22   24...60   20...60  AF26Z-30-00-21 1SBL236001R2100  20.0...24.0  TF42-24  1SAZ711201R1051
                    100...250  100...250  AF26-30-00-13  1SBL237001R1300
          15   29   24...60   20...60  AF30Z-30-00-21 1SBL276001R2100  29.0...35.0  TF42-35  1SAZ711201R1053
                    100...250  100...250  AF30-30-00-13  1SBL277001R1300
          18.5  35  24...60   20...60  AF38Z-30-00-21 1SBL296001R2100  35.0...38.0/40.0 TF42-38  1SAZ711201R1055
                    100...250  100...250  AF38-30-00-13  1SBL297001R1300
          18.5  35  24...60   20...60  AF40-30-00-11  1SBL347001R1100  30.0...40.0  TF65-40  1SAZ811201R1003
                    100...250  100...250  AF40-30-00-13  1SBL347001R1300
          22   41   24…60  20…60  AF52-30-00-11  1SBL367001R1100  36.00…47.0  TF65-47  1SAZ811201R1004
                    100-250  100-250  AF52-30-00-13  1SBL367001R1300
          30   55   24…60  20…60  AF65-30-00-11  1SBL387001R1100  50.0…60.0  TF65-60  1SAZ811201R1006
                    100-250  100-250  AF65-30-00-13  1SBL387001R1300
          37   66   24…60  20…60  AF80-30-00-11  1SBL397001R1100  57.0…68.0  TF96-68  1SAZ911201R1003
                    100-250  100-250  AF80-30-00-13  1SBL397001R1300
          45   80   24…60  20…60  AF96-30-00-11  1SBL407001R1100  75.0..87.0  TF96-87  1SAZ911201R1005
                    100-250  100-250  AF96-30-00-13  1SBL407001R1300
          55   97   24…60  20…60  AF116-30-11-11  1SFL427001R1111  80…110  TF140DU-110  1SAZ431201R1002
                    100-250  100-250  AF116-30-11-13  1SFL427001R1311
          75   132  24…60  20…60  AF140-30-11-11  1SFL447001R1111  100…135  TF140DU-135  1SAZ431201R1003
                    100-250  100-250  AF140-30-11-13  1SFL447001R1311
          90   160  24…60  20…60  AF190-30-11-11  1SFL487002R1111  130…175  TA200DU-175  1SAZ411201R1005
                    100-250  100-250  AF190-30-11-13  1SFL487002R1311
          110  195  24…60  20…60  AF205-30-11-11  1SFL527002R1111  150…200  TA200DU-200 1SAZ411201R1006
                    100-250  100-250  AF205-30-11-13  1SFL527002R1311
          (1) For other control voltages, see "Voltage code table".
          Note : for rated power above 110 kW, refer to "Starters protected by electronic overload relays".
          (2) AF ... -11 not suitable for direct control by PLC-output.