8/4 ABB MOTOR CONTROL AND PROTECTION FOR ROLLING STOCK APPLICATIONS
—
DOL and reversing starters protected by manual motor starters
With AF..B contactors - open type version in kit form
Application
Full voltage direct-on-line (DOL) starting and reversing starting for controlling three-phase
asynchronous motors is a simple and economic solution characterised by a high starting torque
I >
(1.9 to 2.1 times full-speed torque) and a starting current 5.5 to 7 times nominal current.
I C
/In /Cn
7
6
I
5
I = current
4 C = torque
In = nominal current
3
Cn = nominal torque
2
C
1
1SBC101546V0014 0 10 30 60 80 100
The contactor and the manual motor starter control and protect motors against overload and
DOL starter Coordination types
MS132-10B + BEA16-4 short-circuits according to coordination types 1 and 2 (IEC 60947-4-1 / EN 60947-4-1) defining
+ AF09ZB-30-10 the anticipated level of service continuity as follow:
Type 1: In short-circuit conditions, the contactor or starter does not endanger persons or
installations and will not be able to then operate without being repaired or having parts
replaced.
Type 2: In short-circuit conditions, the contactor or starter does not endanger persons or
installations and will be able to operate afterwards. The risk of contacts light welding is
acceptable.
I >
Main Technical Data
Standards IEC 60947-4-1 / EN 60947-4-1, IEC 60947-2 / EN 60947-2
IEC 60947-5-1 / EN 60947-5-1
IEC 61373 Category 1 Class B
Applicable parts of IEC 60077-1/2 and EN 50155
Rated operational voltage Ue max. 690 V - 50/60 Hz
Rated insulation voltage Ui
acc. to IEC 60947-4-1 690 V
acc. to UL / CSA 600 V
Switching frequency ≤ 15 starts/hour - 80 % max. load factor - with max. 1.5 s starting time
1SBC101547V0014 Ambient air temperature use with MS132-B ≤ 60 °C
≤ 30 starts/hour - 50 % max. load factor - with max. 1.5 s starting time
Close to the device
Degree of protection
Fixing IP20
On rail acc. to Manual motor starter on 35 x 7.5 mm or 35 x 15 mm rail
Reversing starter
MS132-10B + BEA16-4 + BER16-4 IEC 60715, EN 60715 Contactor fitted with BEA-..4 connecting link and fixed by:
+ VEM4 + AF09ZB-30-10
- 2 x M4 screws on the bottom side for direct-on-line starter 1 direction
- 2 x M4 screws place diagonally for reversing starter
Note: the difference of depth between manual motor starter and contactors must
be compensated with the use of washers or spacers (not supplied)
By screws Manual motor starter fitted with 2 screw fixing kits FS116 by 2 x M4 screws on the top side
(not supplied)
08
Contactor fitted with BEA-..4 connecting link and fixed by :
- 2 x M4 screws on the bottom side for direct-on-line starter 1 direction
- 2 x M4 screws place diagonally for reversing starter
Mounting positions
1SBC100248S0201
Pos. 1 Pos. 5 Pos. 1
Pos. 5
DOL starters Reversing starters