Page 394 - Contactors_Catalogue
P. 394

8/10             ABB  MOTOR CONTROL AND PROTECTION FOR ROLLING STOCK APPLICATIONS

          —

          DOL and reversing starters protected by manual motor starters
          With AF..B contactors - open type version in kit form
          Wiring diagrams


          Direct-on-line starters
          Power circuit                        1-phase              AC or DC local control  AC or DC remote control
                                                                    KM1:5/L3               KM1:5/L3
                                                                                                  Q1
                               1/L1  3/L2  5/L3    1/L1  3/L2  5/L3     Us  33  Q1  34     Us  33  34
                                     33  43             33  43
                     Q1
                                     34  44             34  44
                              I> I> I>            I> I> I>                     O                 O
                               2/T1  4/T2  6/T3    2/T1  4/T2  6/T3               13                     13
                                                                            I   KM1              I     KM1
                               1/L1  3/L2  5/L3    1/L1  3/L2  5/L3               14                     14
                           A1        13                 13
                        KM1
                           A2        14                 14                        A1                     A1
                               2/T1  4/T2  6/T3    2/T1  4/T2  6/T3     Us  Q1  KM1           Us  Q1  KM1
                                                                    N  43  44     A2       N     43  44  A2

                                                                    KM1:3/L2               KM1:3/L2
                                 V
                               U   W             U  V
                                M                 M
                                ~
                                                  ~
          Reversing starters

          Power circuit                                      AC or DC local control
                                                             KM2:5/L3

                     1/L1  3/L2  5/L3                        Us     33  Q1  34
                          33  43                                               O
          Q1
                          34  44
                    I> I> I>
                                                                          .3     .3
                     2/T1  4/T2  6/T3                                I  KM1  II   KM2
                                                                          .4     .4
                                                                                                  With VM
                     1/L1  3/L2  5/L3     1/L1  3/L2  5/L3    With VEM4  01     01                 21      21
                 A1                   A1                                (2)       (2)            KM2     KM1
             KM1                   KM2                                                             22      22
                                                                                                  A1      A1
                 A2                   A2                               KM1         KM2           KM1        KM2
                     2/T1  4/T2  6/T3     2/T1  4/T2  6/T3   Us  43  Q1  44  A2  (1)  A2          A2      A2
                                                             N
                                                                             (3)
                                                             KM2:3/L2
                                                              AC or DC remote control
                      V
                     U  W
                      M                                      KM2:5/L3
                      ~                                      Us     33  Q1  34

                                                                   O
   08
                                                                II
                                                                          .3     .3
                                                                       KM1    KM2
                                                                          .4     .4
                                                                 I
                                                                                                  With VM
                                                              With VEM4  01     01                 21      21
                                                                        (2)      (2)             KM2     KM1
                                                                                                   22      22
                                                                                                  A1      A1
                                                                       KM1        KM2            KM1        KM2
                                                                 Us  43  Q1  44  A2  (1)  A2      A2      A2
                                                             N
                                                                             (3)
                                                             KM2:3/L2
                                                                                                                  1SBC100253S0201
                                                              Note:    - VEM4 = VM4 (1) + VE4 (2) with A2-A2 (3) connection.
   389   390   391   392   393   394   395   396   397   398   399