Page 397 - Contactors_Catalogue
P. 397
ABB MOTOR CONTROL AND PROTECTION FOR ROLLING STOCK APPLICATIONS 8/13
—
DOL and reversing starters protected by overload relays
With AF..B contactors - Open type version in kit form
Application
Full voltage direct-on-line and reversing starting for controlling three-phase asynchronous
motors is a simple and economic solution characterised by a high starting torque (1.9 to 2.1 times
full-speed torque) and a starting current 5.5 to 7 times nominal current.
I C
/In /Cn
7
6 I
1SBC101548V0014 5 4 I = current
C = torque
3 In = nominal current
Cn = nominal torque
AF09ZB-30-10 + TF42-B
2
C
1
0 10 30 60 80 100
Coordination Types
The contactor, the short-circuit protection device and the thermal overload relay control and
protect motors against overload and short-circuits according to coordination types 1 and 2
(IEC 60947-4-1 / EN 60947-4-1) defining the anticipated level of service continuity as follow:
Type 1: In short-circuit conditions, the contactor or starter does not endanger persons or
installations and will not be able to then operate without being repaired or having parts replaced.
Type 2: In short-circuit conditions, the contactor or starter does not endanger persons or
installations and will be able to operate afterwards. The risk of contacts light welding is
acceptable.
Main Technical Data
Standards IEC 60947-4-1 / EN 60947-4-1
IEC 60947-5-1 / EN 60947-5-1
IEC 61373 Category 1 Class B
Applicable parts of IEC 60077-1/2 and EN 50155
Rated operational voltage Ue max. 690 V - 50/60 Hz
Rated insulation voltage Ui 690 V
1SBC101549V0014 Ambient air temperature 600 V
acc. to IEC 60947-4-1
acc. to UL / CSA
Close to the device
AF09ZB-30-10 + BER16-4 + VEM4 use with TF42-B (acc. to IEC 60947-1) ≤ 60 °C (TF42-B: 38 A above ≤ 50 °C)
+ TF42-B Degree of protection IP20
Switching frequency Refer to "Switching frequency diagrams" page
Fixing
On rail acc. to Contactor on 35 x 7.5 mm or 35 x 15 mm rail
IEC 60715, EN 60715 Overload relay fitted on contactor or on separate assembling with DB42 single mounting kit 08
By screws (not supplied) Contactor 2 x M4 screws placed diagonally
Overload relay fitted on contactor or on separate assembling with DB42 single mounting kit
Mounting positions
1SBC100256S0201
Pos. 1 Pos. 1
Direct-on-line Reversing