Page 397 - Contactors_Catalogue
P. 397

ABB  MOTOR CONTROL AND PROTECTION FOR ROLLING STOCK APPLICATIONS                 8/13

          —

          DOL and reversing starters protected by overload relays
          With AF..B contactors - Open type version in kit form




                                    Application
                                    Full voltage direct-on-line and reversing starting for controlling three-phase asynchronous
                                    motors is a simple and economic solution characterised by a high starting torque (1.9 to 2.1 times
                                    full-speed torque) and a starting current 5.5 to 7 times nominal current.
                                    I  C
                                    /In  /Cn
                                    7
                                    6           I
                     1SBC101548V0014  5 4                     I = current
                                                              C = torque
                                    3                         In = nominal current
                                                              Cn = nominal torque
          AF09ZB-30-10 + TF42-B
                                    2
                                            C
                                    1
                                    0  10  30    60  80  100




                                    Coordination Types
                                    The contactor, the short-circuit protection device and the thermal overload relay control and
                                    protect motors against overload and short-circuits according to coordination types 1 and 2
                                    (IEC 60947-4-1 / EN 60947-4-1) defining the anticipated level of service continuity as follow:
                                    Type 1: In short-circuit conditions, the contactor or starter does not endanger persons or
                                    installations and will not be able to then operate without being repaired or having parts replaced.
                                    Type 2: In short-circuit conditions, the contactor or starter does not endanger persons or
                                    installations and will be able to operate afterwards. The risk of contacts light welding is
                                    acceptable.




                                    Main Technical Data
                                    Standards                      IEC 60947-4-1 / EN 60947-4-1
                                                                   IEC 60947-5-1 / EN 60947-5-1
                                                                   IEC 61373 Category 1 Class B
                                                                   Applicable parts of IEC 60077-1/2 and EN 50155
                                    Rated operational voltage Ue max.  690 V - 50/60 Hz
                                    Rated insulation voltage Ui    690 V
                           1SBC101549V0014  Ambient air temperature  600 V
                                      acc. to IEC 60947-4-1
                                      acc. to UL / CSA
                                      Close to the device
          AF09ZB-30-10 + BER16-4 + VEM4   use with TF42-B (acc. to IEC 60947-1)  ≤ 60 °C (TF42-B: 38 A above ≤ 50 °C)
          + TF42-B                  Degree of protection           IP20
                                    Switching frequency            Refer to "Switching frequency diagrams" page
                                    Fixing
                                      On rail acc. to       Contactor on 35 x 7.5 mm or 35 x 15 mm rail
                                      IEC 60715, EN 60715  Overload relay fitted on contactor or on separate assembling with DB42 single mounting kit  08
                                      By screws (not supplied)  Contactor 2 x M4 screws placed diagonally
                                                          Overload relay fitted on contactor or on separate assembling with DB42 single mounting kit

                                    Mounting positions







                                                                                                                    1SBC100256S0201
                                     Pos. 1               Pos. 1
                                    Direct-on-line       Reversing
   392   393   394   395   396   397   398   399   400   401   402