Page 80 - Contactors_Catalogue
P. 80

3/28             ABB  MOTOR CONTROL AND PROTECTION FOR ROLLING STOCK APPLICATIONS

          —

          AF116B ... AF370B  3-pole contactors
          Technical data





          General technical data
          Contactor types                    AF116B  AF140B   AF146B  AF190B   AF205B  AF265B   AF305B  AF370B
          Rated insulation voltage Ui
            acc. to IEC 60947-4-1            1000 V
            acc. to UL / CSA                 600 V
          Rated impulse withstand voltage Uimp.  8 kV
          Electromagnetic compatibility      Devices complying with IEC 60947-1/EN 60947-1 - Environment A
          Ambient air temperature close to contactor
            Operation  Fitted with thermal overload relay  -25 to +55 °C
   03
                    Without thermal overload relay  -40 to +70 °C
            Storage                          -40 to +70 °C
          Climatic withstand                 Category B according to IEC 60947-1 - Annex Q
          Maximum operating altitude (without derating)  3000 m
          Mechanical durability
            Number of operating cycles       5 million operating cycles
            Maximum switching frequency      300 cycles/h
          Shock and vibration withstand
          acc to IEC 61373                   Category 1, class B

          Magnet system characteristics
          Contactor types                   AF116B   AF140B  AF146B   AF190B  AF205B   AF265B  AF305B   AF370B
          Coil operating limits       AC supply At θ ≤ 70 °C 0.85 x Uc min ... 1.1 x Uc max
          acc. to IEC 60947-4-1       DC supply At θ ≤ 70 °C 0.80 x Uc min ... 1.1 x Uc max
          Rated control circuit voltage Uc  24...500 V AC, 20...500 V DC
           Coil consumption
              DC control voltage
              20...60 V DC      Average pull-in value 210 W           205 W            400 W
                               Average holding value 2.5 W            2.5 W            3.5 W
              48...130 V DC     Average pull-in value 130 W           130 W            360 W
                               Average holding value 2.5 W            2.5 W            2.5 W
              100...250 V DC    Average pull-in value 135 W           190 W            410 W
                               Average holding value 3 W              2.5 W            4.5 W
              250...500 V DC    Average pull-in value 205 W           190 W            600 W
                               Average holding value 4 W              4 W              4.7 W
              AC control voltage 50/60 Hz
              24...60 V AC      Average pull-in value 225 VA          165 VA           475 VA
                               Average holding value 5.5 VA           6 VA             8.5 VA
              48...130 V AC     Average pull-in value 170 VA          175 VA           340 VA
                               Average holding value 4 VA             4 VA             17 VA
              100...250 V AC    Average pull-in value 130 VA          220 VA           385 VA
                               Average holding value 6 VA             7 VA             17.5 VA
              250...500 V AC    Average pull-in value 205 VA          185 VA           420 VA
                               Average holding value 16 VA            16 VA            21 VA
              Max. permitted control voltage    Rated control circuit voltage / Max. permitted control voltage
              during voltage fluctuation defined    24 ... 60 V AC 50/60 Hz / 66 V AC 50/60 Hz
              acc. to IEC 60077 / EN 50155  48 ... 130 V AC 50/60 Hz / 143 V AC 50/60 Hz
                                            100 ... 250 V AC 50/60 Hz / 275 V AC 50/60 Hz
                                            250 ... 500 V AC 50/60 Hz / 550 V AC 50/60 Hz
          Drop-out voltage                  55 % of Uc min
          Operating time
          Coil supply between A1 - A2
           Between coil energization and:  N.O. contact closing 20...55 ms  25...60 ms  30...60 ms
           Between coil de-energization and:  N.O. contact opening 40..70 ms  45...80 ms  45...80 ms

          Mounting characteristics and conditions for use
          Contactor types                   AF116B   AF140B  AF146B   AF190B  AF205B   AF265B  AF305B   AF370B
          Mounting positions                    Pos. 2    +30°  -30°

                                            Pos. 4
                                                    Pos. 3
                                                  Pos. 1     Pos. 1 ± 30°  Pos. 5  Pos. 6
                                            Max. add-on N.O. or N.C. auxiliary contacts: see accessory fitting details for 3-pole contactor
                                            AF116B ... AF370B
          Mounting distances                The contactors can be assembled side by side
          Fixing                                                                                                 1SFC101278C0201
           On rail acc. to IEC 60715, EN 60715  –
           By screws (not supplied)         4 x M4                    4 x M5
   75   76   77   78   79   80   81   82   83   84   85