Page 6 - DEHN-protects-photovoltaic-systems
P. 6

Buildings with PV installations                                                                                            A        Main distribution board                                                     Part No.

                                                                                                                                                        DEHNventil    (depending on the system configuration)               951 315
            With external lighting protection and sufficient separation distance                                                                        The combined arrester is mounted directly at the entrance point to the building.    (TT)
                                                                                                                                                        It protects the electrical installation in the direct environment and, thanks to the    951 405
                                                                                                                                                                                                                             (TNS)
                                                                                                                                                        patented RADAX Flow Technology, offers high follow current limitation and thus    951 305
                                                                                                                                                        maximum system availability.                                         (TNC)
                                                                                                                                        B        Data interface                                                             Part No.

                                                                                                                                                        BLITZDUCTOR XTU
                                                                                                                                                        The combined arrester protects balanced data interfaces (e.g. RS 485).  920 349
                                                                                                                                                        Via the integrated actiVsense Technology the arrester automatically detects    (Module)
                                                                                                                                                                                                                            920 300
                                                                                                                                                        the operating voltage of the useful signal and optimally adapts the voltage    (Base Part)
                                                                                                                                                        protection level to it.
                                                   D  B C
                                                                                                                                        C        PV installation                                                            Part No.
                                                                                                                                                        DEHNguard M YPV                                                     952 565
                                                                                                                                                        This type 2 arrester is specially designed for application in PV systems and protects    (1170 V)
                              C                                                                                                                         the DC side of the inverter against surges from inductive couplings. If there is more
                                                                                                                                                        than 10 metres of cable between the PV system and the inverter, a further arrester    952 567
               E                                                                                                                                        is necessary in the roof area.                                      (1500 V)
                                                         F
                                                                                                                                                        alternatively: DEHNcube YPV SCI 1000
                                                                                                                                                        Type 2 arrester DEHNcube YPV SCI provides comprehensive protection for a PV system in    900 910
                                                                                                                                                                                                                            (1 MPPT)
                                                                                                                                                        an enclosure. It is mounted directly upstream of the inverter and is available in two versions,
                                                                                                                                                        1 MPPT and 2 MPPT. If there is more than 10 metres of cable between the PV system and    900 920
                                                                                                                                                        the inverter, a further arrester is necessary in the roof area.     (2 MPPT)
                                                                                                                                       D        AC side inverter                                                            Part No.
                                                                                                                                                        DEHNguard    M TNS or DEHNguard M TT                                952 405
                                                                                                                                                        The surge arrester protects against overvoltages from inductive couplings by distant    (TNS)
                                                                                                                                                        lightning strikes and from switching overvoltages.  If there is more than 10 metres of
                                                                                                                                                        cable between the service entrance box and the inverter, a further type 2 surge arrester    952 315
                                                                                                                                                        is required at the inverter.                                         (TT)
                                                                                                                                        E        Equipotential bonding                                                      Part No.

                                                                                                                                                        UNI earthing clamps/saddle clamps                                   540 250
                                                                                                                                                        The clamps are suitable for integrating the mounting systems of PV installations
                                                                                                                                                        in the functional equipotential bonding / the functional earthing or the    365 250
                                            A      B                                                                                                    lightning equipotential bonding.

                                                                                                                                        F        External lightning protection
                                                                                                                                                        HVI   Conductor
                                                                                                                                                        With the high-voltage-resistant insulated down conductors it is possible
                                                                                                                                                        to make optimum use of the roof surface whilst still maintaining the
                                                                                                                                                        separation distance from conductive parts.




            The PV modules must be located in the protected volume of the isolated
            air-termination system – whilst also maintaining the separation distance “s”.


            It is always advisable to favour a lightning protection system   If the cable is longer than 10 metres, e.g., between the
            which, taking the required separation distance into account,   grid connection point and the inverter, additional type 2
            has no direct connection with the PV power supply system.   surge protective devices are required. Battery storage
            The HVI Conductor by DEHN comes into its own here.  systems which are less than 10 m away from the point

            High-voltage-resistant insulated down conductors make it   where the surge protective device is installed are also
            possible to maintain an equivalent separation distance of,   protected.
            e.g., s ≤ 0.75 m (in air) and still make optimum use of the                                                               Further info on the topic of lightning and surge protection
                                                                                                                                      for modern industrial buildings can be found on our website.
            roof surface.
                                                                                                                                       www.de.hn/pvip
            Type 2 arresters are used on the DC side to protect the
            module and the inverter. The AC side is protected by a
            combined arrester near the grid connection. On both the                                                                   We are here to support you with any technical queries:
            AC and DC sides, the protective devices are installed as                                                                  Team Support
                                                                                                                                      Telephone: +49 9181 906 1750
            closely as possible to the device to be protected.                                                                        E-Mail: [email protected]


    10                                                                                                                                                                                                                                    11
   1   2   3   4   5   6   7   8   9   10