Smoke / heat extraction systems, fire alarm systems,

 voice alarm systems




 Technical fire protection equipment and especially fire alarm   material losses but, above all, consequential damage such as
 systems are of vital importance. They enable modern   production downtime, loss of data or the appointment of a
 buildings with elaborate architecture and both a complex   fire watch should the fire alarm system fail.
 infrastructure and purpose to easily meet today’s fire   Coordinated lightning and surge protection according to of
 protection and safety requirements.   Surge protection        Application / interface  Type          Part No.
 IEC 62305-4 prevents false alarms or destruction resulting
 The systems are used for fire detection, alarming and   from atmospheric discharges or switching overvoltages at   Smoke / heat extraction system
 evacuation and thus serve the protection of people and   the corresponding transitions of the relevant lightning   DEHNpatch Class E  LAN connection to building   DPA M CLE RJ45B 48 929 121
 material assets. A further critical task as a superordinate   protection zone and increases system availability.   Universal arrester for Industrial Ethernet,   services management system
 system element is to take over the central function of the   Additional shielding and earthing measures for hazard alarm   PoE+.
 control systems of other safety-related systems and equip-  systems should be taken in accordance with the VdS  2833
 1)
 ment in the event of fire.   DEHNguard M TT 2P                Power supply smoke     DG M TT 2P 275  952 110
 guideline (see also DIN VDE 0845 - appendix 1). Moreover, it
 Lightning strikes and voltage surges can cause irreparable   should be checked whether additional surge arresters are   Modular surge arrester for single-phase TT   extraction system
                              and TN systems.
 damage to electrical and electronic equipment that is not   required due to the indicators listed in the VdS 2833
 adequately protected. In addition to electrical consumers   guidelines. If this is the case, the operator of the hazard
 and telecommunications equipment, this applies to safety   alarm system must be informed of the necessity for protec-  BLITZDUCTORconnect  Actuator, air intake dampers,  BCO ML2 BD 24  927 244
 systems such as fire alarms, voice alarms or heat/smoke   tion measures.  Space-saving, modular combined arrester   alarms
 extraction systems. The damage not only includes purely   with a width of 6 mm and push-in connec-
                              tion technology.
                              BLITZDUCTOR XT                   Actuator air intake dampers   BXT ML4 BE 36   920 336
                              Combined arrester with RFID LifeCheck for   (24 V DC/AC; 5 W)  BXT BAS  920 300
                              protecting 4 single lines sharing a common              (Application up to
                              reference potential.                                    max. 1.8 A)
 230 V  230 V  230 V
 SDB  SDB  TE  SDB  MP  M     or
 < 10 m  < 10 m  telecoms  < 10 m
 distribution board           DEHNguard S                                             or                   or
                              Universal surge arrester                                DG S 48 FM      952 098
 BMS  alarm FACP  FBKD
 SHES  FACP  VAS  Fire alarm system
 alarming areas 1..n
                              DEHNguard M TN                   Power supply           DG M TN 275     952 200
                              Modular surge arrester for single-phase TN   alarm panel 230 V
                              systems.
 smoke suction   NAD  NAD
 system
                              BLITZDUCTOR XT                   Ring bus fire alarm system  BXT ML4 BE 24  920 324
 FBIOS  combination  SD  LS  LS  Combined arrester with RFID LifeCheck for            BXT BAS         920 300
 OSD/AST
                              protecting 4 single lines sharing a common
 ventilation button           reference potential.
 M  AST  SD  LS  LS           DEHNrail                         Alarm contact e.g. to lift con-  DR M 2P 255  953 200
                              Two-pole surge arrester consisting of a base   trol, ventilation, sprinkler
 domelight                    part and plug-in protection module.
 line coupler  line coupler
 OST  C  C
 EX  EX                       BLITZDUCTOR XT or -VT            Conductor key depot    BXT ML2 BD S 24  920 244
 rain / weather               Space-saving, modular combined arrester                 BXT BAS         920 300
 sensor  external loudspeaker  with a width of 6 mm and push-in connec-               or                   or
 sprinkler  lift              tion technology.                 Heating                BVT ALD         918 408
 BMS:  Building management system  AST:   Acoustic signal transmitter   LS:   Loudspeaker   BLITZDUCTOR XT  Telecommunication   BXT ML4 B 180  920 310
 SDB:  Sub distribution board   FACP:  Fire Alarm Control Panel  MP:   Micro phone  Space-saving four-pole lightning current   connection  BXT BAS  920 300
 SHES:  Smoke and heat extraction system  FBIOS:  Fire brigade information / operating system  VAS:  Voice alarm system  arrester with RFID LifeCheck for almost all
 FBKD:  Fire brigade key depot  applications.
 NAD:  Not automatic detector
 OST:  Optical signal transmitter
 OSD:  Optical smoke detector  Public address systems - voice alarm
 SD:   Smoke detector         DEHNvario                        Public address systems -   DVR 2 BY S 150 FM  928 430
 TE:   Telecoms
                              Combined arrester for protecting electro-  line loudspeaker
                              acoustic systems.