Safety equipment                               Application               Type            Part No.
             Arc fault protection system DEHNshort – components:
             1                    Quenching device QD II    Quenching of the arc fault < 5 ms  DSRT QD II  782 002
                                  Quenching device unit for direct
                                  connection to the detection
                                  devices


             2                    Fibre optical cable       Connection between the central   DSRT LWL 4.00  782 024
 1-5                              Connecting cable 4 m      and quenching device



             3                    Detection device          Connection of the current trans-  DSRT DD CPS BACA  782 030
                                  (current and light)       formers and activation of the
                                                            quenching devices




             4                    Detection device          Connection of the fibre optical   DSRT DD FS BAAA  782 050
                                  For light detection       sensors
 Personal and system protection –

 Arc fault protection system DEHNshort  5  Fibre optic sensor  Monitoring of a panel (example)  DSRT FS 12 1.5  782 085
                                  Sensor length 12 m
 Active arc fault protection - This means protection of employees working on
 electrotechnical systems and maximum system availability.  Safety equipment according to the 5 safety rules in line with EN 50110-1

                                  Disconnect completely     Switching stick up to 36 kV  SCS 36 2000  763 612
 In a hospital, a power failure is immediately life-threatening.   In addition, people working in and on electrical installations   Fuse tong for HH fuses  SZ HH W20 1500  765 052
 The top priority is system availability. A power failure must   must be protected. The operator must eliminate all accident   Secure against re-connection  Insulating blade for NH2 and NH3   SE NH2 3  785 644
 never happen in a hospital. Think of patients in the opera-  risks and prevent personal injury. To prevent electrical   for distribution blocks
 ting theatre, on artificial respiration or other life-supporting   accidents, the five safety rules defined in the EN 50110-1
 measures. The active arc fault protection system DEHNshort   standard apply. DEHN offers suitable products for applying   Verify that the installation is   Voltage detector for medium-  PHE4 6 20 S  783 235
                                                            voltage installations 6-20 kV
                                  dead
 supports your system concept and reduces downtime   the five safety rules as well as the personal protective
 resulting from arc faults to a minimum.  equipment necessary to protect people from arc faults.  Carry out earthing and short-  Earthing and short-circuiting   EKV3+1 120 G   VAAG-
                                  circuiting                device with earthing stick for            7KZ
                                                            transformer substations   ES SK STK 1000  761 001

 > I  Lines:
 ––– Current transformer (CT)  Personal protective equipment DEHNcare (PPE against the thermal effects of an arc fault)
 > L  ––– Fibre optic sensor (FS)
 DEHNshort  DEHNshort
 POWER ERROR  DEHNshort POWER ERROR  POWER ERROR  DEHNshort POWER ERROR  Safety helmet for electricians  white  ESH U 1000 S SW  785 706
 T1 T2  T3 T4  T1,T3,T4 T2,T4  T1 T2  T3 T4  T1,T3,T4 T2,T4
 S1 S2  IL1 IL2  S1 S2  S1 S2  IL1 IL2  S1 S2  ––– Light information (> L)v
 S3 S4  IL3 Io  S3 S4  S4 S3  IL3 Io  S4 S3
 QD  QD  QD  QD
 BO1 BI1 BI2  HSO1 HSO2  BI1 BI2 BO1  BI1 BO1 BI2  HSO1 HSO2  BI1 BI2 BO1
 ––– Overcurrent information (> I)
 SET  SET  SET  SET
 DSRT DD CPS .... ARC  PROTECTION  DSRT DD PS .... ARC  PROTECTION  DSRT DD CPS .... ARC  PROTECTION  DSRT DD PS .... ARC  PROTECTION
 ––– Activation of shunt release (T)
 ––– Activation of quenching devices   Face shield          With active protection, arc-fault-  APS T AS CL2 SC  785 821
 (optical fibre cable)                                       tested
 Circuit breaker – ACB
                                  Protective gloves         With long gauntlet, arc-fault-  APG 10 L  785 810
                                                            tested
 Transformer
                                  Protective coat           Arc-fault-tested          APC 52 54       785 756
 Quenching device – QD II
 Current transformer (CT)
 transformer 1  transformer 2  coupling
 NH fused feeder


 DEHNshort
 DEHNshort POWER ERROR
 Detection devices: CPS  T1 T2 S1 S2 S3 S4  T3 T4 IL1 IL2 IL3 Io  FS  T1,T3,T4 T2,T4 S1 S2 S3 S4
 POWER
 ERROR
 BO1 QD BI1 BI2  HSO1 HSO2  BI1 QD BI2 BO1
 SET  SET
 DSRT DD CPS .... ARC  PROTECTION  DSRT DD PS .... ARC  PROTECTION
      More information at:           Use our online configurators