1/100            ELECTRICAL INSTALL ATION SOLUTIONS FOR BUILDINGS   2CHC 420 001 C0201
  1



          —
          Miniature circuit-breakers
          SN 201 series - 1P+N in one module housing




                                                                                                                                 SN 201 L                                 SN 201                         SN 201 M
                            General Data          Standards                                                                      IEC/EN 60898
                                                  Poles                                                                          1P + N
                                                  Tripping characteristics                                                       B, C                                     B, C, D                        B, C
                                                  Rated current I n                               A                              2…40 A  *1
                                                  Rated frequency f                               Hz                             50 / 60 Hz
                                                  Rated insulation voltage U  acc. to DIN EN 60664-1  V                          500 V AC
                                                                    i
                                                  Overvoltage category                                                           III
          SN 201
                                                  Pollution degree                                                               2
                            Data acc. to IEC/EN 60898-1  Rated operational voltage U n            V                              230 V AC
                                                  Max. power frequency recovery voltage (U  )     V                              254 V AC 1P: 60 V DC 1P+N: 125 V DC
                                                                               max
                                                  Min. operating voltage                          V                              12 V AC - 12 V DC
                                                  Rated short-circuit capacity I                  kA                             4.5 kA                                   6 kA                           10 kA
                                                                      cn
                                                  Rated making and breaking capacity of one individual pole I  kA                4.5 kA                                   6 kA                           6 kA
                                                                                           cn1
                                                  Energy limiting class (B, C up to 40A)                                         3
                                                  Rated impulse withstand voltage U   (1.2/50µs)  kV                             4 kV (test voltage 6,2kV at sea level, 5kV at 2000m)
                                                                          imp.
                                                  Dielectric test voltage                         kV                             2.5 kV (50 / 60Hz, 1 min.)
                                                  Reference temperature for tripping characteristics  °C                         30°C
                                                  Electrical endurance                            operations                     10.000 operations
                            Data acc. to IEC/EN 60947-2  Rated ultimate short-circuit breaking capacity I cu  kA                 6 kA                                     10 kA                          10 kA
                                                  Rated service short-circuit breaking capacity I  kA                            4.5 kA                                   6 kA                           7.5 kA
                                                                                  cs
                            Mechanical Data       Housing                                                                        Insulation group II, RAL 7035
                                                  Toggle                                                                         Insulation group IIIA, black, sealable in ON/OFF positions
                                                  Contact position indication                                                    Marking on toggle (I ON / 0 OFF)
                                                  Protection degree acc. to EN 60529                                             Housing: IP4X; Terminals: IP2X
                                                  Mechanical endurance                            operations                     20.000 operations
                                                  Shock resistance acc. to IEC/EN 60068-2-27                                     30 g - 2 shocks - 13 ms
                                                  Vibration resistance acc. to IEC/EN 60068-2-6                                  0.35mm or 5g - 20 cycles at 5…150…5 Hz without load
                                                  Environmental conditions (damp heat) acc. to IEC/EN 60068-2-30  °C/RH          28 cycles with 55°C/90-96% and 25°C/95-100%
                                                  Ambient temperature (with daily average ≤ +35°C)  °C                           -25 … +55°C
                                                  Storage temperature                             °C                             -40 … +70°C
                            Installation          Cross-section of conductors (top/bottom) Stranded / Solid  mm 2                16 mm  / 16 mm 2
                                                                                                                                      2
                                                  Cross-section of conductors (top/bottom) Flexible  mm 2                        10 mm  / 10 mm 2
                                                                                                                                      2
                                                  Tightening Torque                               Nm                             1.2 Nm
                                                  Mounting                                                                       On DIN rail 35 mm acc. to EN 60715 by fast clip
                                                  Mounting Position                                                              any
                                                  Supply                                                                         optional (supply from top/bottom)
                            Dimensions and weight  Pole dimensions (H x D x W)                    mm                             85 x 68.9 x 17.6 mm
                                                  Pole weight                                     g                              ca. 110 g
                            Combination with aux. ele-  Auxiliary contact                                                        Yes
                            ments                 Signal contact/auxiliary switch                                                Yes
                                                  Shunt trip                                                                     Yes (with coupling interface)
                                                  Undervoltage release                                                           Yes (with coupling interface)
                           *1  SN201 and SN201M series in B and D characteristic are available for rated current In ≥ 6 A