Page 1118 - Din prodcuts 2020
P. 1118

11/12            ELECTRICAL INSTALL ATION SOLUTIONS FOR BUILDINGS   2CHC 420 001 C0201




          —
          carat®
          Dimmers




          Product    Article-No.    Order-No.       Pack/Qty  Product     Article-No.    Order-No.       Pack/Qty


                                      3
                                       4
                                         5
                     Busch-touch dimmer  )  )  )  )  )  )                 Busch-rotary dimmer  )  )  )  )  )
                                   1
                                     2
                                                                                           3
                                                                                            4
                                                                                              5
                                          6
                                                                                        1
                                                                                          2
                     Flush-mounted, LED, 2-100 W                          flush mounted, RL, 20-500 W
                     Touch dimmer.                                        With rotary control, 2way On-Off switching and
                     2-wire connection (neutral conductor not required)   soft-catch.
                     Neutral conductor optionally connectable             Leading Edge control.
                     (recommended for the connection of low loads         For incandescent lamps, 230 V tungsten halogen
                     < 10 W/VA). Optimised for dimming of retrofit LED    lamps and low-volt halogen lamps with conventional
                     lamps (LEDi). For incandescent lamps, 230V tungsten   transformer.
                     halogen lamps and low-voltage halogen lamps with     With adjustable minimum brightness.
                     conventional transformers or electronic transformers   Without cover plate.
                     and dimmable halogen energy-saving lamps.            Rated voltage: 230 V~, +10 % / -10 %
                     Mix operaton of LEDi with conventional loads possible.  Rated frequency: 50 Hz
                     With adjustable minimum brightness.                  Rated power: 20 - 500 W/VA
                     The minimum brightness for the leading edge control   IEC 60669-2-1, British Standard EN 60669-2-1
                     can be adjusted using the potentiometer.
                     The potentiometer at the left limit stop corresponds
                     with the trailing edge control mode.                 2247 U-500     2CKA006512A0302  1/10
                     Low-noise level by MOSFET transistors.   1)  Illuminable with neon lamp. Neon lamp included in delivery with cover plate.
                     With electronic short-circuit protection.  2)  In the case of conventional transformers, take ~20% transformer loss into account.
                     With electronic overload protection.     3)  Provided with terminal for net disconnection devices.
                     With light-level memory and minimum brightness   4)  Also  applicable for 1gang 2way installations.
                     memory. Operation also possible via conventional push   5)  Only in conjunction with standard flush-mounting boxes according to DIN 49073,
                     buttons (2020 US, 2021/6 UK).             Part 1, erect or Busch-Jaeger No. 3040 wallbox stonework, 3050 wallbox cavity wall
                     Without control cover.                    or 3060 wallbox concrete)
                     For control cover with control lamp 6543-xxx-10x.
                     For Busch-Remote control IR control cover 6066-xxx-10x.            1  2  3  4  5  6
                     For comfort timer control element 6455-101-500.      Busch-rotary dimmer  )  )  )  )  )  )
  11
                     For Busch-Watchdog Presence tech 6813-xxx-101 und    UP, RL, 200-700 W
                     6813/11-xxx.                                         With rotary control, 2way On-Off switching and
                     Nominal power: 2 - 100 W/VA (retrofit LED loads).    soft-catch.
                     Nominal power: 10 - 200 W/VA (non-LED loads).        Leading Edge control.
                     Rated voltage: 230 V~, +10 % / -10 %                 For incandescent lamps, 230 V tungsten halogen
                     Rated frequency: 50 Hz - 60 Hz                       lamps and low-volt halogen lamps with conventional
                     Protection class (Device): IP 20                     transformer.
                     Temperature range (Device): 0 °C to 35 °CIEC 60669-2-1,   Short-circuit-proof, overload-protected.
                     British Standard EN 60669-2-1                        With adjustable minimum brightness.
                                                                          Without cover plate.
                                                                          Without claws.
                                                                          Rated voltage: 230 V~, +10 % / -10 %
                     6526 U-500     2CKA006512A0323  1/10                 Rated frequency: 50 Hz
          1)  Illuminable with neon lamp. Neon lamp included in delivery with cover plate.  Rated power: 200 - 700 W/VA
          2)  In the case of conventional transformers, take ~20% transformer loss into account.  IEC 60669-2-1, British Standard EN 60669-2-1
          3)  In case of electronic transformers, 5 % transformer losses.
          4)  Only in conjunction with standard flush-mounting boxes according to DIN 49073,

          Part 1, erect or Busch-Jaeger No. 3040 wallbox stonework, 3050 wallbox cavity wall
          or 3060 wallbox concrete)                                       6520 U-500     2CKA006520A0227  1/10
          5)  Recommendation: Please use loads and types of one producer.
                                                              1)  Illuminable with neon lamp. Neon lamp included in delivery with cover plate.
          6)  In connection with 6810-21x-101 and 6800-xx-104 (M) only suitable for switching
                                                              2)  In the case of conventional transformers, take ~20% transformer loss into account.
          retrofit LEDs (for 2-conductor connection).         3)  Provided with terminal for net disconnection devices.
                                                              4)  Also  applicable for 1gang 2way installations.
                                                              5)  Only in conjunction with standard flush-mounting boxes according to DIN 49073,
                                     2
                                    1
                     Busch-rotary dimmer  )  )  )  )           Part 1, erect or Busch-Jaeger No. 3040 wallbox stonework, 3050 wallbox cavity wall
                                      3
                                        4
                     flush mounted, R, 60-600 W                or 3060 wallbox concrete)
                     With rotary control, 2way On-Off switching and   6)  Should be mounted in a seperate wallbox.
                     soft-catch. Leading Edge control.
                     For incandescent lamps and 230 V tungsten halogen
                     lamps. With adjustable minimum brightness.
                     Without cover plate.
                     Rated voltage: 230 V~, +10 % / -10 %
                     Rated frequency: 50 Hz
                     Rated power: 60 - 600 W
                     IEC 60669-2-1, British Standard EN 60669-2-1

                     2250 U-500     2CKA006515A0848  1/10
          1)  Illuminable with neon lamp. Neon lamp included in delivery with cover plate.
          2)  Also  applicable for 1gang 2way installations.
          3)  Only in conjunction with standard flush-mounting boxes according to DIN 49073,
          Part 1, erect or Busch-Jaeger No. 3040 wallbox stonework, 3050 wallbox cavity wall
          or 3060 wallbox concrete)
          4)  Provided with terminal for net disconnection devices.
   1113   1114   1115   1116   1117   1118   1119   1120   1121   1122   1123