The S-ARC1 is the new 1P+N Arc Fault Detection Device (AFDD) with an integrated Miniature Circuit
Breaker (MCB) in only two module width. Besides the overcurrent protection of the MCB, the S-ARC1
provides additional protection against series, parallel and earth arc faults. The series is perfectly in- 3
tegrated with ABB’s System pro M compact® range. Combined with a Residual Current Circuit
Breaker (RCCB) as upstream device, the S-ARC1 provides the best solution for complete protection
of electrical installations in buildings.
1/2 1/2 N N
AFDD indications
S-ARC1S-ARC1
TESTAFDD
1 ONI ON
1/2 1/2 N N
1 blink/sec
S-ARC1S-ARC1
TESTAFDD
2/1 2/1 N N
1/2 1/2 1 ONI ON N
N
2 blink/sec S-ARC1
S-ARC1
TESTAFDD
2/1 2/1 N N U > 275 V
1 ONI ON
1/2 N 1/2 N
3 blink/sec S-ARC1
S-ARC1
TEST TEST
1/2 2/1 2/1 or N N N
1 ON 1 ON Internal
S-ARC1
LED for easy troubleshooting Blink/ Signalling AFDD self test
failure
LED to monitor the correct working LED color sec duration Cause of trip 1/2 1/2 I ON N N 2/1 N N
2/1
Manual trip,
conditions of the device and have an Green Permanent manual test , S-ARC1S-ARC1
easier troubleshooting in case of trip. overcurrent 2/1 TESTAFDD
Consequently the downtime for main- Red 1 5 sec Series arc 1/2 N 1/2 N ON
1 ON N I ON
S-ARC1
tenance can be reduced. blinking TEST AFDD RCD DS-ARC1
– Toggle ON: GREEN LED Red 2 5 sec Parallel arc 2/1 2/1 1 ON N N OOFF I∆ > I∆n
blinking
– Toggle OFF: LED OFF Red Only DS-ARC1
– Different indications after the trip, blinking 3 5 sec Over voltage 2CSA423002D0202
2/1 N
after reclosing the toggle Dedicated sticker for LED
– Possibility to recall in memory the In case of internal self test failure, the Dedicated sticker that summarizes the
last tripping due to arc fault and led can switch off or start blinking LED function is present in addition to
overvoltage green/red alternatively.
the instructions sheet.
Double slot terminals Compatibility with busbars All information on the device
Fail-safe terminals to avoid improper A quick and easy installation is possi- Main technical information are laser-
connection. Two slots of different di- ble in one step using a standard printed on the front and left side of
mensions (25 mm and 10 mm ) avail- ABB System pro M compact® busbar: product to ensure long readability.
2
2
able to allow the connection both with no additional cables required for the
cables and busbars. Connection possi- wiring.
ble both from top and bottom side.
Standard System pro M compact® clip
ensures a stable fixing on DIN rail and
easy and fast mounting and dismount-
ing operations.