          Auxiliary elements for
          MCBs S 200, SN 201, RCDs F 200, DS 200, DS201-DS202C, DS203NC,
          DSE201 M, AFDD S-ARC1 and Switch disconnectors SD 200 series

                                                                                                                       4
                                    Auxiliary contact and signal/auxiliary contact
                                                                     S2C-S/H6R, S2C-H6R, S2C-H11L, S2C-H20L and S2C-H02L
                                                                     AC14 1A/400V, 2A/230V - DC12 1A/220V, 1,5A/110V -
                                    Utilization category
                                                                     DC13 2A/60V, 4A/24V
                                    Conventional free air thermal current  A  10
                                    Min. operational current/voltage*  10 mA at 12 V; 5 mA at 24 V
                                    Rated conditional short-circuit   V  230 V AC 1,000 A with S201 K4
                Auxiliary elements  current
                                    Overvoltage category             III
                                    Rated impuls withstand voltage
                                    (1.2/50µs)                 kV    4
                                                                     0.75…2.5 (up to 2 x 1.5 mm2 for S2C-H11L, S2C-H20L and
                                    Cross-section of conductors  mm 2
                                                                     S2C-H02L)
                                    Tightening torque          Nm    1.2 (max. 0.8 for S2C-H11L, S2C-H20L and S2C-H02L)
                                    Contact stability in vibration test   5g, 20 sweep cycles 5…150…5 Hz at 24 V AC/DC, 5 mA
                                    according to IEC/EN 60 068-2-6   automatic reclosing < 10 ms
                                    Mechanical service life          10000 operations
                                    Dimensions (H x D x W)     mm    85 x 69 x 8.8

                                    Auxiliary contact and signal/auxiliary contact
                                                                     S2C-H6-11R, S2C-H6-20R, S2C-H6-02R
                                                                     AC14: 1A/400V, 2A/230V
                                    Utilization category
                                                                     DC12/DC13: 1A/50V, 2A/30V
                                    Conventional free air thermal current  A  10
                                    Min. rated operational current/  10 mA at 12 V; 5 mA at 24 V
                                    voltage*
                                    Rated conditional short-circuit
                                    current                    V     230 V AC 1,000 A with S201 K4
                                    Overvoltage category             III
                                    Rated impuls withstand voltage
                                    (1.2/50µs)                 kV    4
                                    Cross-section of conductors  mm 2  0.75…2.5
                                    Tightening torque          Nm    1.2
                                    Contact stability in vibration test   5g. 20 sweep cycles 5...150...5 Hz at 24 V AC/DC. 5mA
                                    according to IEC/EN 60068-2-6    automatic reclosing < 10 ms
                                    Mechanical service life          10000 operations
                                    Dimensions (H x D x W)     mm    85 x 69 x 8.8