Page 21 - DS225 Modern-buildings
P. 21

Protection of lighting systems  Find out more at:  Upholding the infrastructure                  Find out more at:
 www.de.hn/led-en
                                                                                                  www.de.hn/tbse
 Surge protection for LED lights  Surge protection for technical building services




 Surge arresters protect sensitive LED technology from damage, thus preventing cost-   Surge arresters ensure that the basic supply structures of technical
 intensive failure, time-consuming repair and expensive replacement of the LED light.  building services are stable and reliable.



 Damage caused by surges   Protective devices prevent failure  Closing security gaps


 Although LED lights have many advantages, their short-  Powerful surge arresters protect sensitive LED technology,   Technical  building  services  include  heating,  ventilation,  sanitary  engineering,  air-conditioning  and  electrical  engineering,
 comings over traditional luminaires are that they are more    preventing damage and ensuring the long service life of   as well as measuring, control and regulation technology. All these services access the power and data systems of the building.
 susceptible to surge damage and that the cost of replacement   LED lights. This reduces replacement costs and avoids time-   However, this also means that operators rely on the protection measures for the electric devices in these systems. But what
 is higher. Such unnecessary costs are easily avoided!  consuming and costly maintenance work. Another advan-  happens if there are gaps? Central components of the technical building services are then vulnerable to, e.g., dangerous
 tage: reliable LED lighting ensures uninterrupted work and   surges. As a result, the heating or ventilation system might no longer work after a thunderstorm and important measuring
 It is not only direct lightning strikes that cause damage.     production processes and, therefore, satisfied users.  and / or control technology could be destroyed.
 Indirect lightning effects often cause surges which exceed
 the immunity of sensitive LED lights many times over. This   Prevent damage and implement a comprehensive    Observing framework conditions
 results in partial or complete failure of the LED modules and   surge protection concept:
 destruction of the LED drivers. Another risk factor for LED     ‚ Directly at the LED light / light strip.  IEC 60364-5-53 clause 534 calls for separate surge arresters directly at the consumer (e.g. air-conditioning containers or
 lights is network-generated surges caused by, for example,   heating sensor) if the cable length from the upstream electrical connection exceeds 10 m. This is an important aspect which is
 switching operations which lead to premature ageing of the     ‚ In the upstream sub-distribution board.  often neglected in technical building services equipment.
 LED light.
            Technical building services equipment in modern buildings is interconnected and interdependent. Many components interact,
            for example, in the power system, to optimise consumption and save resources. Shading and heating systems or air-conditioning
            and ventilation processes are controlled by specified temperatures or solar radiation. If a single component fails, the function of
            the entire system is affected.


 Surge protection   Surge protection
 Distribution box  At the light strip  Sub-distribution board  Protection of the DALI control  Sub-distribution board  Information technology    Bus systems KNX / EIB  Industrial Ethernet / PoE++
 Power supply  Power supply  Power supply
             Power supply            for RS 485              Power supply            Data technology




 DEHNshield TNS FM  DEHNcord L 2P SN1860  DEHNguard M TNS 275 FM  BUStector
             DEHNguard M TT ACI 275 FM  BLITZDUCTOR HF 5     BUStector M 1 220 FM    DEHNpatch Class E
 Part No. 941 405  Part No. 999 937  Part No. 952 405  Part No. 925 001
             Part No. 952 341        Part No. 920 300 / 920 371  Part No. 925 001    Part No. 929 121


 20                                                                                                                 21
   16   17   18   19   20   21   22   23   24