Page 2 - Electronic_fuses
P. 2
1/4" x 1-1/4" Fuses
ABC Series, Fast Acting, Ceramic Tube
Description
• Fast-acting, ceramic tube
• Optional leaded version available
• 1/4 x 1-1/4 (6.3mm x 32mm) physical size
• Ceramic tube, nickel-plated brass endcap construction
• UL Listed product meets standard 248-14
ELECTRICAL CHARACTERISTICS
% of Amp Rating Opening Time
110% 4 Hours Minimum
135% 60 Minutes maximum
200% 120 Seconds Maximum
mm
Approvals Dimensions ( ⁄in)
Drawing Not to Scale
• UL Listed Guide & File numbers (ABC 1/4 - 15A):
JDYX & E19180.
• UL Recognition Guide & File numbers (ABC 20 - 30A):
JDYX2 & E19180.
• CSA Certification Record No: 053787 C 000 &
Class No: 1422 01 & 1422 30.
Environmental Data
• Shock: 1/4A and 1/2A – MIL-STD-202,
Method 213, Test Condition I;
1A thru 30A – MIL-STD-202, Method 207,
(HI Shock)
• Vibration: 1/4A thru 30A – MIL-STD-202,
Method 204, Test Condition C (Except 5g, 500HZ)
Ordering
• Specify product code, option code and packaging code
SPECIFICATIONS
Product Voltage AC Interrupting DC Interrupting Typical DC Cold Typical Typical
Code Rating Rating Rating Resistance** Melting I t† Voltage
2
AC DC 250V 125V 125V 75V (ohms) AC Drop‡
ABC-1/4 250V 125V 35A 10000A 10000A - 3.000 0.02 3.25
ABC-1/2 250V 125V 35A 10000A 10000A - 0.788 0.19 0.51
ABC-3/4 250V 125V 35A 10000A 10000A - 0.303 0.8 0.42
ABC-1 250V 125V 35A 10000A 10000A - 0.197 1.4 0.35
ABC-1-1/2 250V 125V 100A 10000A 10000A - 0.1175 2.9 0.35
ABC-2 250V 125V 100A 10000A 10000A - 0.0755 4.2 0.25
ABC-2-1/2 250V 125V 100A 10000A 10000A - 0.05875 8.53 0.26
ABC-3 250V 125V 100A 10000A 10000A - 0.0435 19.5 0.25
ABC-4 250V 125V 200A 10000A 10000A - 0.02975 29.1 0.25
ABC-5 250V 125V 200A 10000A 10000A - 0.0286 16.4 0.23
ABC-6 250V 125V 200A 10000A 10000A - 0.02315 31.6 0.24
ABC-7 250V 125V 200A 10000A 10000A - 0.0183 73.2 0.20
ABC-8 250V 125V 200A 10000A 10000A - 0.0146 111.9 0.17
ABC-10 250V 125V 200A 10000A 10000A - 0.01205 215.6 0.15
ABC-12 250V 125V 750A 10000A 10000A - 0.0068 129.6 0.11
ABC-15 250V 125V 750A 10000A 10000A - 0.005425 200.2 0.12
ABC-20 250V 125V 400A 1000A 10000A - 0.00366 550.8 0.13
ABC-25 125V 125V - 1000A 400A 1000A 0.00263 839.3 0.12
ABC-30 125V 125V - 1000A 400A 1000A 0.002225 1,429 0.14
** DC Cold Resistance (Measured at ≤10% of rated current)
†Typical Melting I t (A Sec) (I t was measured at listed interrupting rating and rated voltage. Measured at 70% to 80% power factor on AC)
2
2
2
‡Typical Voltage Drop (Voltage drop was measured at 25°C±3°C ambient temperature at rated current)