Page 2 - Electronic_fuses
P. 2

1/4" x 1-1/4" Fuses
                                                                ABC Series, Fast Acting, Ceramic Tube


            Description
            • Fast-acting, ceramic tube
            • Optional leaded version available
            • 1/4 x 1-1/4 (6.3mm x 32mm) physical size
            • Ceramic tube, nickel-plated brass endcap construction
            • UL Listed product meets standard 248-14
                      ELECTRICAL CHARACTERISTICS
               % of Amp Rating            Opening Time
                    110%                 4 Hours Minimum
                    135%               60 Minutes maximum
                    200%              120 Seconds Maximum
                                                                                mm
            Approvals                                               Dimensions ( ⁄in)
                                                                    Drawing Not to Scale
            • UL Listed Guide & File numbers (ABC 1/4 - 15A):
              JDYX & E19180.
            • UL Recognition Guide & File numbers (ABC 20 - 30A):
              JDYX2 & E19180.
            • CSA Certification Record No: 053787 C 000 &
              Class No: 1422 01 & 1422 30.
            Environmental Data
            • Shock: 1/4A and 1/2A – MIL-STD-202,
              Method 213, Test Condition I;
              1A thru 30A – MIL-STD-202, Method 207,
              (HI Shock)
            • Vibration: 1/4A thru 30A – MIL-STD-202,
              Method 204, Test Condition C (Except 5g, 500HZ)
            Ordering
            • Specify product code, option code and packaging code





                                                       SPECIFICATIONS
            Product          Voltage        AC Interrupting  DC Interrupting  Typical DC Cold   Typical     Typical
            Code              Rating           Rating            Rating        Resistance**    Melting I t†  Voltage
                                                                                                      2
                           AC      DC      250V     125V     125V     75V         (ohms)          AC        Drop‡
             ABC-1/4      250V     125V     35A    10000A   10000A      -         3.000           0.02       3.25
             ABC-1/2      250V     125V     35A    10000A   10000A      -         0.788           0.19       0.51
             ABC-3/4      250V     125V     35A    10000A   10000A      -         0.303           0.8        0.42
             ABC-1        250V     125V     35A    10000A   10000A      -         0.197           1.4        0.35
             ABC-1-1/2    250V     125V    100A    10000A   10000A      -         0.1175          2.9        0.35
             ABC-2        250V     125V    100A    10000A   10000A      -         0.0755          4.2        0.25
             ABC-2-1/2    250V     125V    100A    10000A   10000A      -        0.05875          8.53       0.26
             ABC-3        250V     125V    100A    10000A   10000A      -         0.0435          19.5       0.25
             ABC-4        250V     125V    200A    10000A   10000A      -        0.02975          29.1       0.25
             ABC-5        250V     125V    200A    10000A   10000A      -         0.0286          16.4       0.23
             ABC-6        250V     125V    200A    10000A   10000A      -        0.02315          31.6       0.24
             ABC-7        250V     125V    200A    10000A   10000A      -         0.0183          73.2       0.20
             ABC-8        250V     125V    200A    10000A   10000A      -         0.0146         111.9       0.17
             ABC-10       250V     125V    200A    10000A   10000A      -        0.01205         215.6       0.15
             ABC-12       250V     125V    750A    10000A   10000A      -         0.0068         129.6       0.11
             ABC-15       250V     125V    750A    10000A   10000A      -        0.005425        200.2       0.12
             ABC-20       250V     125V    400A     1000A   10000A      -        0.00366         550.8       0.13
             ABC-25       125V     125V      -      1000A    400A    1000A       0.00263         839.3       0.12
             ABC-30       125V     125V      -      1000A    400A    1000A       0.002225        1,429       0.14
            ** DC Cold Resistance (Measured at ≤10% of rated current)
            †Typical Melting I t (A Sec) (I t was measured at listed interrupting rating and rated voltage. Measured at 70% to 80% power factor on AC)
                               2
                        2
                          2
            ‡Typical Voltage Drop (Voltage drop was measured at 25°C±3°C ambient temperature at rated current)