82               SAFETY SWITCHES AND ENCLOSED SWITCH-DISCONNECTORS SAFE AND DEPENDABLE PERFORMANCE



          —

          Technical data
          Fire rated enclosed switch-disconnectors








          —
          Enclosed switch-disconnectors, types OKA and OKL class F200 and F300.
          Technical data according to IEC 60529 and IEC 60947-3
          Type/size                         OKA20_    OKA40_     OK_63_    OKA80_    OKL100_  OKL125_F2_  OKL125_F3_
          Rated insulation voltage           750 V      750 V     750 V      750 V     750 V      750 V      750 V
          Rated thermal current and rated   40ºC  20 A  40 A       63 A      80 A      100 A      125 A      125 A
          operational current AC20/DC20  60ºC  16 A     32 A       50 A      63 A       75 A      100 A      100 A
          Rated operational current, AC-21A   415 V  20 A  40 A    63 A      80 A      100 A      125 A      125 A
          and AC-22A           up to 500V     20 A      40 A       63 A      80 A      100 A      125 A      125 A
                                   690V       20 A      40 A       63 A      80 A      100 A      125 A      125 A
          Rated operational current, AC-23A  415 V  20 A  23 A     63 A      75 A       80 A      90 A       125 A
                                  500V        20 A      23 A       45 A      58 A       60 A       70 A      125 A
                                   690V       12 A      12 A       20 A      20 A       40 A       50 A      125 A
          Rated conditional short-circuit   50kA, 415V  7 kA  7 kA  13 kA    13 kA      17 kA     18 kA      24 kA
          current r.m.s and corresponding   Fuse size:   40 A/32 A  40 A/32 A  100 A/80 A  100 A/80 A  125 A/125 A  125 A/100 A  200 A/250 A
          cut-off current of the fuse in single-  gG/aM
          phase test according to IEC60269  50kA, 690V  4 kA  4 kA  11 kA    11 kA     10 kA      12 kA      24 kA
                                Fuse size:   25 A/16 A  25 A/16 A  80 A/63 A  80 A/63 A  63 A/63 A  125 A/100 A  200 A/250 A
                                  gG/aM
          Rated frequency                50 Hz/60 Hz  50 Hz/60 Hz  50 Hz/60 Hz  50 Hz/60 Hz  50 Hz/60 Hz  50 Hz/60 Hz  50 Hz/60 Hz
          Cu-wire size suitable for terminal.   0.75-10 mm 2  0.75-10 mm 2  1.5-25 mm 2  1.5-25 mm 2  10-70 mm 2  10-70 mm 2  M8x25 mm 2
          Terminal bolt size
          Used switch type                  OT40_      OT40_      OT63_     OT80_     OT100_    OT125F_   OT160EV_


          Type/size                         OKL160_   OKL200_    OKL250_    OKL315_   OKL400_   OKL570_    OKL720_
          Rated insulation voltage           1000 V     1000 V    1000 V     1000 V    1000 V     1000 V    1000 V
          Rated thermal current and rated oper-  40ºC  160 A  200 A  250 A   315 A      400 A     570 A      720 A
          ational current AC20/DC20  60ºC     125 A     200 A      250 A     315 A      320 A     460 A      580 A
          Rated operational current, AC-21A   up to 415 V  160 A  200 A  250 A  315 A   400 A     570 A      720 A
          and AC-22A             up to 500V   160 A     200 A      250 A     315 A      400 A     570 A      720 A
                                    690V      160 A     200 A      250 A     315 A      400 A     570 A      720 A
          Rated operational current, AC-23A  up to 415V  160 A  200 A  250 A  315 A     400 A     570 A      720 A
                                    440V      160 A     200 A      250 A     315 A      400 A     570 A      720 A
                                    500V      160 A     200 A      250 A     315 A      400 A     570 A      720 A
                                    690V      160 A     200 A      250 A     315 A      400 A     570 A      720 A
          Rated conditional short-circuit current   100kA, 500V  24 kA  40.5 kA  40.5 kA  59 kA  59 kA  90 kA  90 kA
          r.m.s and corresponding cut-off   Fuse size:   200 A/250 A  355 A/315 A  335 A/315 A  500 A/500 A  500 A/500 A  800 A/1000 A  800 A/1000 A
          current of the fuse in sing-  gG/aM
          le-phase test according to IEC60269
                                50kA, 690V    24 kA     35 kA      35 kA     51 kA      51 kA     72 kA      72 kA
                                 Fuse size:   200 A/250 A  355 A/315 A  355 A/315 A  500 A/500 A  500 A/500 A  800 A/1000 A  800 A/1000 A
                                   gG/aM
          Rated frequency                 50 Hz/60 Hz  50 Hz/60 Hz  50 Hz/60 Hz  50 Hz/60 Hz  50 Hz/60 Hz  50 Hz/60 Hz  50 Hz/60 Hz
          Terminal bolt size               M8x25 mm 2  M8x25 mm 2  M8x25 mm 2  M10x30 mm 2  M10x30 mm 2  M12x40 mm 2  M12x40 mm 2

          Used switch type                  OT160EV_   OT200_     OT250_    OT315_    OT400_     OT630_    OT800_