Page 43 - IDEC relay catalogue
P. 43
Relays & Sockets RY/RM Series
Specifications
Standard Contact Bifurcated Contact
Contact Model
RY2 - DPDT Slim RM2 - DPDT Wide RY4 - 4PDT RY22 - DPDT / RY42 - 4PDT
Contact Material Gold-plated silver Silver Gold-plated silver Silver-palladium alloy
Contact Resistance 1 50 mΩ maximum 30 mΩ maximum 50 mΩ maximum 100 mΩ minimum Switches & Pilot Lights
24V DC, 5 mA; 5V DC, 24V DC, 10 mA; 5V DC, 24V DC, 5 mA; 5V DC,
Minimum Applicable Load 1V DC, 100 μA (reference value)
10 mA (reference value) 20 mA (reference value) 10 mA (reference value)
Operate Time 2 20 ms maximum
Release Time 2 20 ms maximum
Power Consumption AC: 1.1 VA (50 Hz), 1 VA (60 Hz) AC: 1.4 VA (50 Hz), 1.2 VA (60 Hz) AC: 1.4 VA (50 Hz), 1.2 VA (60 Hz) AC: 1.1 VA (50 Hz), 1 VA (60 Hz)
(approx.) DC: 0.8W DC: 0.9W DC: 0.9W DC: 0.8W
Insulation Resistance 100 MΩ minimum (500V DC megger)
Between live and dead parts:
1500V AC, 1 minute 2000V AC, 1 minute 2000V AC, 1 minute 1500V AC, 1 minute 3 Display Lights
Between contact and coil:
1500V AC, 1 minute 2000V AC, 1 minute 2000V AC, 1 minute 1500V AC, 1 minute
Dielectric Strength 3
Between contacts of different poles:
1500V AC, 1 minute 2000V AC, 1 minute 2000V AC, 1 minute 1500V AC, 1 minute
Between contacts of the same pole:
1000V AC, 1 minute 1000V AC, 1 minute 1000V AC, 1 minute 1000V AC, 1 minute
Electrical: 1800 operations/h maximum
Operating Frequency
Mechanical: 18,000 operations/h maximum Relays & Sockets
Damage limits: 10 to 55 Hz, amplitude 0.5 mm
Vibration Resistance
Operating extremes: 10 to 55 Hz, amplitude 0.5 mm
Damage limits: 1000 m/s 2
Shock Resistance
2
2
Operating extremes: 100 m/s (DPDT Slim), 200 m/s (4PDT, DPDT Wide)
Mechanical Life 50,000,000 operations
100,000 operations (220V AC, 5A)
Electrical Life 200,000 operations (220V AC, 3A) 500,000 operations (220V AC, 5A) 200,000 operations (110V AC, 1A)
200,000 operations (220V AC, 3A)
Operating Temperature 4 –25 to +55°C (no freezing) –25 to +45°C (no freezing) –25 to +55°C (no freezing) 5 –25 to +55°C (no freezing)
Operating Humidity 45 to 85% RH (no condensation)
Weight (approx.) 23g 35g 34g RY22: 23g / RY42: 34g Timers
Note: Above values are initial values. 3. Relays with indicator or diode: 1000V AC, 1 minute 5. When the total current of 4 contacts
1. Measured using 5V DC, 1A voltage drop method 4. For use under different temperature conditions, refer to is less than 15A, the operating tempera-
2. Measured at the rated voltage (at 20°C), excluding contact bouncing Continuous Load Current vs. Operating Temperature Curve. ture range is –25 to +70°C.
Release time of relays with diode: 40 ms maximum The operating temperature range of relays with indicator or diode is –25 to +40°C. Terminal Blocks