Page 44 - IDEC relay catalogue
P. 44
RY/RM Series Relays & Sockets
AC Coil Ratings Rated Current (mA) ±15% at 20°C Coil Resistance (Ω) Operation Characteristics
Switches & Pilot Lights Voltage (V) DPDT AC 50Hz 4PDT DPDT AC 60Hz 4PDT DPDT DPDT Wide & Max. Continuous Pickup Dropout
±10% at 20°C
(against rated values at 20ºC)
DPDT Wide &
DPDT Wide &
Slim
Slim
Slim
Applied Voltage
Voltage
Voltage
4PDT
240
150
170
9.4
6
200
18.8
12
86
76.8
39.3
100
121
75
24
37
300
42
—
110 9.6 60.5 8.4 50 6,950 153
—
—
30%
110-120 — 9.4-10.8 — 8.0-9.2 — 4,290 110% 80% maximum
minimum
120 8.6 — 7.5 — 25,892 —
8,100
Display Lights 220-240 4.9 4.7-5.4 4.3 4.0-4.6 26,710 18,820
4.7
220
—
—
4.1
—
—
—
—
240
—
—
—
DC Coil Ratings
Rated Current (mA) Coil Resistance (Ω) Operation Characteristics
±15% at 20°C ±10% at 20°C (against rated values at 20ºC)
Voltage (V)
DPDT Wide & Max. Continuous Pickup Dropout
DPDT Slim DPDT Wide & 4PDT DPDT Slim
4PDT Applied Voltage Voltage Voltage
Relays & Sockets 12 64 36.9 188 160 110% 80% maximum 10% minimum
47
150
6
128
40
75
24
750
32
650
18
48
2,600
18.5
100-110 — 8.2-9.0 2,660 12,250
—
110 8 — 13,800 —
Contact Ratings UL Ratings (Standard Contact)
Maximum Contact Capacity Voltage Resistive General use
Allowable Contact Power
Timers Contact Continuous Resistive Load Inductive Load Voltage (V) Rated Load Ind. Load DPDT DPDT 4PDT DPDT DPDT 4PDT
Wide
Wide
Slim
Slim
Current
Res. Load
110V AC 3A 1.5A 240V AC 3A 5A 5A 0.8A 2A 5A
DPDT Slim 3A 660 VA AC 176 VA AC 220V AC 3A 0.8A 120V AC — — — 1.5A 2.5A —
(RY2) 90W DC 45W DC
30V DC 3A 1.5A 100V DC 0.2A 0.4A 0.2A 0.2A — 0.2A
30V DC 3A 5A 5A 3A — 5A
110V AC 5A 2.5A
DPDT Wide 1100VA AC 440VA AC
(RM2) 5A 150W DC 75W DC 220V AC 5A 2A CSA Ratings (Standard Contact)
30V DC 5A 2.5A Resistive General use
Terminal Blocks 4PDT (RY4) 5A 1200 VA AC 288 VA AC 110V AC 5A 0.5A Voltage DPDT DPDT 4PDT DPDT DPDT 4PDT
1.2A
5A
240V AC
60W DC
150W DC
2A
30V DC
Wide
Wide
Slim
Slim
1A
Bifurcated
3A
2A
5A
5A
240V AC
5A
0.8A
Contact
30W DC
15W DC
(RY22/ 1A 176 VA AC 88 VA AC 220V AC 0.8A 0.4A 120V AC 3A 5A — 1.5A 2.5A —
RY42) 30V DC 1A 0.5A 100V DC — — — 0.2A 0.4A 0.2A
Note: Inductive load for the rated load — cos ø = 0.3, L/R = 7 ms 30V DC 3A 5A 5A 1.5A 2.5A 1.5A
TÜV Ratings (Standard Contact) UL Ratings (Bifurcated Contact) CSA Ratings (Bifurcated Contact)
Circuit Breakers Voltage Slim Wide 4PDT 240V AC 0.8A 0.4A 240V AC 0.8A 0.4A
Resistive
Voltage
Voltage
DPDT
DPDT
General use
General use
Resistive
240V AC
5A
3A
5A
120V AC
0.5A
0.5A
1A
120V AC
1A
3A
5A
30V DC
AC: cos ø = 1.0, DC: L/R = 0 ms 5A 30V DC 1A 0.5A 30V DC 1A —
766 www.idec.com