Page 58 - IDEC relay catalogue
P. 58

RY2KS Series                                                            Relays & Sockets



         Specifications      Gold-plated silver
         Contact Material
     Switches & Pilot Lights  Contact Resistance  50 mΩ maximum (initial value)

                            25 ms maximum (at the rated voltage)
         Set Time
         Reset Time
                            25 ms maximum (at the rated voltage)
                            AC:
         Power Consumption
                                   1.6 VA (50 Hz), 1.5 VA (60 Hz)
         (approx.)
                                   1.2W
                            DC:
                            100 MΩ minimum (500V DC megger)
         Insulation Resistance
                            Between live and dead parts:    1,500V AC, 1 minute
                            Between contact and coil:   1,000V AC, 1 minute
         Dielectric Strength
                            Between contacts of different poles: 1,000V AC, 1 minute
                            Between contacts of the same pole:  700V AC, 1 minute
     Display Lights  Operating Frequency  Mechanical: 18,000 operations/h maximum
                            Electrical: 1800 operations/h maximum
         Temperature Rise
                            Coil: 85°C maximum, Contact: 65°C maximum
                                   2
                            0 to 60 m/s  (maximum frequency: 55 Hz),
         Vibration Resistance
                            Frequency: 5 to 55 Hz, Amplitude: 0.5 mm
                                 2
         Shock Resistance   200 m/s  minimum
         Mechanical Life    5,000,000 operations minimum
         Electrical Life    200,000 operations minimum
         Operating Temperature  –5 to +40°C (no freezing)
     Relays & Sockets   Coil Ratings  Rated Current (mA) ±15% at 20°C  Coil Resistance (Ω)   Operation Characteristics (values at 20°C)
                            67g
         Weight (approx.)
         Rated Voltage (V)

                                           250
                            260
                                                           6.3
                6          50Hz            60Hz         ±10% at 20°C  Maximum Continuous Applied Voltage   Set and Reset Voltage
           AC (50/60Hz)  12  120           115            30.3                110%                   maximum
                                                                                                       80%
                            58
                                            56
                                                           132
                24
                120
                                                           30
                6           11.2    200    10.8           3,840
     Timers  DC  12                 100                    120                110%                     80%
                24
                                    50
                                                           480
                48                  25                    1,920                                      maximum
                110                 11                    10,000
         Contact Ratings                                                     UL Ratings
                          Maximum Contact Capacity                             Voltage    Resistive     General use
                          Allowable Contact Power  Rated Load                  240V AC      3A             0.8A
     Terminal Blocks  Voltage  Current  Resistive   Inductive   Voltage   Res.   Load  30V DC  3A          —
         Switching  Continuous
                                                                                                           1.5A
                                                                               120V AC
                                                         Ind.
                                                                                            3A
                                                   Load
                                              (V)
                                     Load
                            Load
                                                    3A
                                                         1.5A
                                            110 AC
          250V AC
          125V DC   3A     600VA AC  176VA AC  220 AC  3A  0.8A              CSA Ratings  Resistive     General use
                           90W DC
                                                                               Voltage
                                    45W DC
                                                    3A
                                                         1.5A
                                             30 DC
                                            100V DC  0.2A  0.12A               240V AC      3A             0.8A
                                                                               120V AC      3A             1.5A
             Note: Inductive load for the rated load — cos ø = 0.3, L/R = 7 ms
                                                                               30V DC       3A             1.5A
     Circuit Breakers
      780                                               www.idec.com
   53   54   55   56   57   58   59   60   61   62   63