Page 60 - IDEC relay catalogue
P. 60

RY2KS Series                                                            Relays & Sockets


        Through Panel Mount Socket
         SY4S-51
     Switches & Pilot Lights  31  27  3  Panel Thickness:  Terminal Arrangement  +0.2  0  25.6  [27 (N–1) + 21.4]  +0.5 0
                       1 to 2
                                   1 2
                                     3 4
                                   5 6
                                     7 8
                            25.4
                                    10 11
                                      12
                                   9
                                      14
                                   13
                          0.3
                                 (Bottom View)
                                                  N: No. of sockets mounted
                                            5.4 min.∗
                     11
                     18.7
                                           ∗ 10.4 min. when using hold-down springs
                 2.4
            21.2
     Display Lights  PCB Mount Sockets          13.2    13.8 min.  SY4S-62                            13.2  8.2 min.∗∗
         SY4S-61
                            Terminal Arrangement  10.4  4.1  8.8  4.4              Terminal Arrangement  4.4 4.1  8.8
                                1 2  3 4                                               1 2  3 4
                                  7 8
          31              25.4  5 6 10 11 12  16.8           9  29              0.3    5 6 10 11 7 8 12  16.8  10.4  9
                                9
                                                                                       9
                                13  14                                                13  14
             27      3  0.3    (Bottom View)                       21.2   3          (Bottom View)  1.4
                    11                   14.2 min.∗   15-ø2 holes           11                              15-ø2 holes
                     15         ∗ 19.2 min. when using  1.4  (Tolerance ±0.1)  15                12.2 min.∗  (Tolerance ±0.1)
     Relays & Sockets  21.2        hold-down springs               1.5                        ∗ ∗∗  17.2 min. when using a hold-down spring.
                 1.5
                                                                                                13.2 min. when using a hold-down spring for
                                                                                                the relay with check button







     Timers










     Terminal Blocks












     Circuit Breakers












      782                                               www.idec.com
   55   56   57   58   59   60   61   62   63   64   65