Page 61 - OTDC Switch
P. 61
ACCESSORIES 61
—
Ordering information for accessories IEC and UL
Auxiliary contacts
Auxiliary contact blocks, IP20
Contact numbering according to EN 50013. The type and the ordering numbers are for one piece.
—
Auxiliary contacts
Mounting under the mechanism cover.
OTDC S1.0 - OTDC100…250E, OTDC100…200U_: Max. 4 test contacts or 2 test contacts + 2 test indication contacts.
OTDC S2.0 - OTDC100…250G, OTDC100…250UG_: Max. 1 test contact + 1 test indication contact.
OTDC M - OTDC315…1000F_, OTDC250…1000UF_: Max. 4 test contacts + 4 test indication contacts. 06
Suitable Pieces/
—
OA1G10, OA3G01 for switches Function Type Order code Package
1NO OA1G10 1SCA022353R4970 10
OTDC100...1000_
1NC OA3G01 1SCA022456R7410 10
—
Module for auxiliary contacts
Screw mounting to the left side of the switch. Max. 8 auxiliary contact blocks with the OEA28 module.
Suitable Pieces/
for switches Type Order code Package
OTDC S1.0 - OTDC100…250E, OTDC100…200U_ OEA28 1SCA022714R8810 1
—
Performance data according to IEC 60947-5-1
For OA1G, OA3G
AC15 DC12 DC13
U /[VAC] I /[A] U /[V DC] I /[A] P/[W] I /[A] P/[W]
e
e
e
e
e
230 6 24 10 240 2 50
400 4 72 4 290 0.8 60
415 4 125 2 250 0.55 70
690 2 250 0.55 140 0.27 70
- - 440 0.1 44 - -