Page 62 - OTDC Switch
P. 62

62               SWITCH-DISCONNECTORS OTDC AND OTDCP




          —
          Ordering information for accessories IEC and UL
          Interlocks












                           —
                           Mechanical/electrical interlock kit
                           OTDC switch-disconnectors can be interlocked in the ON and OFF-position using padlocks or a mechanical/eletrical
                           interlock kit mounted on the mechanism. The diameter of the lock bail can be max 8 mm. Kit includes the mounting
                           hardware. Coil for the electrical interlock needs to be ordered separately.
                           Suitable for switches                         Type            Order code
                           OTDC S1.0       OTDC100...250E_, OTDC100...200U_  OSZT1L      1SCA106538R1001
          —                OTDC M          OTDC250…1000_F_ *)            OTDCZTML        1SCA162042R1001
          OSZT1L
                           *)  Limitations to use of auxiliary contacts, max. 2 test contacts + 2 test indication contacts.

                           —
                           Coils for electrical interlocks
                           The switch can be interlocked electrically in the OFF- and ON-positions by installing a coil inside the housing of the interlock
                           kit. The electrical interlock works using the “closed circuit principle”, meaning that when the control voltage is not
                           connected to the coil.
                                                                                                         Weight/
                                                                                                         unit
          —                Suitable for switches               Type                   Order code         kg
          OTDCZTML         AC coils
                           110V AC, 50 Hz                      PDAL2/110AC50Hz        1SCA106543R1001    0.15
                           110V AC, 60 Hz                      PDAL2/110AC60Hz        1SCA107100R1001    0.15
                           120V AC, 60 Hz                      PDAL2/120AC60Hz        1SCA111353R1001    0.15
                           208V AC, 60 Hz                      PDAL2/208AC60Hz        1SCA107101R1001    0.15
                           230V AC, 50 Hz                      PDAL2/230AC50Hz        1SCA107102R1001    0.15
                           240V AC, 60 Hz                      PDAL2/240AC60Hz        1SCA111356R1001    0.15
          —
          PDAL2            DC coils
                           24V DC                              PDAL2/24DC             1SCA106542R1001    0.15
                           48V DC                              PDAL2/48DC             1SCA107103R1001    0.15
                           110V DC                             PDAL2/110DC            1SCA107105R1001    0.15
                           125V DC                             PDAL2/125DC            1SCA111338R1001    0.15
                           220V DC                             PDAL2/220DC            1SCA112503R1001    0.15
                           Technical data for the coil
                           Operating voltage                   U = 0.8...1.1 x U
                                                                          n
                           Operating ambient temperature       -40°C...+65°C
                           Power consumption                   with AC 6.5W
                                                               with DC 9VA
   57   58   59   60   61   62   63   64   65   66   67