Page 67 - OTDC Switch
P. 67

DIMENSIONAL DR AWINGS                                                              67




         —
         Dimensional drawings
         OTDC S2.0 - 100...250 Amperes (IEC and UL)









         —
         OTDC100, 160, 200, 250G_11, OTDC100, 200, 250UG_11
         OTDC100, 160, 200, 250G_11-ESS, OTDC100, 200, 250UG_11-ESS

                               146                      200...268 (OXP6X210)
                               5.748                   7.88...10.56
                               134
                               5.276
                               116                    120
                               4.567                  4.724
                               106,8
                               4.20
                               96,5               40,6  50,2
                               3.799              1.60  1.98
                               77
                               3.032
                             38,5  28,75
                             1.516  1.132
                                           1                 1
                                                                           45,8                                        07
                                           5 0.197                0.236   1.803
                        2.264
                                         4,2
            165  6.496  142  5.591  115  4.528  101  3.976 57,5  0.165  6
                      50,5  1.988
                                                                             3
                                 25  0.98   56
                                            2.205
                      9         0.394       3 0.118                80
                      0.354   10                                   3.15
                             19,5        74,3  2.93
                             0.768          2
                               2
           A09090
                                                      110
                                                      4.33
          Pos.                              Accessory                         Description
          1                                 Connection bar kit                OTDCKIT250GS101
          2                                 Terminal shroud                   OTDCS200GG1
          3                                 Handle                            OH_65J6






          —
          OTDC100...250GV_K
          OTDC100...250UGV_K













                          A09095



                        63,2                  144,4
                        2.49                  5.69