Page 10 - Smart sensor brochure
P. 10

Subscriptions

             Subscription                 Smart Sensor 2-year subscription      Smart Sensor 5-year subscription
             Part No.                           3AFP9191436                           3AFP9253864
                                      2 years ABB Ability Smart Sensor Subscription.
                                                                        5 years ABB Ability Smart Sensor Subscription. Subscription
             Description           Subscription enables full functionality for the Smart Sensor
                                                                         enables full functionality for the Smart Sensor platform.
                                                 platform.
            Accessories

             Accessory                             Cassia X2000 Bluetooth Gateway
             Part No.                                  3AXD50000872305
                                  X2000 extends Bluetooth connectivity up to 400 meters for Bluetooth 4 and 1 kilometer for
                                  Bluetooth 5 in open space. Supports Power over Ethernet (PoE) and 12 V DC. X2000 can be
             Description
                                   used as a Bluetooth and IP gateway. Internet Protocol (IP) backhaul options includes
                                     Ethernet, 2.4/5 GHz Wi-Fi and USB cellular modem. All weather-proof, IP66-rated.


             Parameters                                              Description                   Availability
             Measured parameters
             Vibration: axial, radial, tangential  mm/s inch/sec, rms                                 •
             Skin temperature                     °C or °F                                            •
             Magnetic field                       (Data not shown; used in calculations)              •
             Accoustic signals                    (Data not shown; used in calculations)              •
                                                                                                      •
             Time                                 MM:dd:hh:mm:ss
             Vibration fft and time waveform      Special report                                      •
             Calculated health parameters
             Overall condition                    Traffic light for consolidated status               •
                                                                                                      •
             overall vibration                    Traffic light, mm/s or inch/sec, rms
             Bearing condition                    Traffic light, integer value                        •
             Misalignment                         Traffic light, %                                    •
             unbalance                            Traffic light                                       •
                                                                                                      •
             Bent shaft                           Traffic light
             Rotor winding health                 Traffic light                                       •
             Calculated operating parameters
             Output power                         kw                                                  •
                                                                                                      •
             Operating hours                      Hours
             Number of starts                     Integer value                                       •
             Speed                                Revolutions per minute (rpm)                        •
             Motor supply frequency               Hz                                                  •
             Loading                              % of name plate full load power                     •
             Torque                               Nm                                                  •
             Direction Of rotation                Clockwise / counterclockwise                        •
             Maintenance advice
             Alerts, alarms, reminders            In app, per e-mail, push, webhook                   •
             Regreasing                           Remaining hours until next regreasing               •
             sensor unit and battery status                                                           •
             Certifications
             Ip 66                                                                                    •
             CE, IC, RCM, EAC, FCC, UL, C-UL, SRE, SUBTEL                                             •
             NEC Intrinsically Safe               Class 1, Div. 2                                     •
             IECEX Intrinsically safe             iB 11B T4 Gb, -40 to +80                            •
             Compatibility
                                                  Frame sizes IEC: 56 - 500 NEMA: 42 - 449, non-standard motors equivalent
             Induction motors                                                                         •
                                                  to IEC 500
             Permanent magnet/synchronous reluctance motors                                           •
             Safe area motors                                                                         •
                                                                                                      •
             Hazardous area motors
             Continuous and intermittent duty                                                         •
             Fixed speed and variable speed                                                           •
             Old and new motors                                                                       •
             ABB and non-ABB motors                                                                   •
      7 | ABB Ability™ Smart Sensor for condition monitoring
   5   6   7   8   9   10   11   12